Device overview
No. Description Setting
010
Heating system
Sets the existing heating system:
Floor heating, standard (FBH St.)
Floor heating, low energy (FBH NE)
• Radiator (RAD)
Convector, passive (KON pas)
Convector, active (KON akt)
0 = FBH St.
1 = FBH NE
2 = RAD
3 = KON pas
4 = KON akt
Standard: 0
020
Blocking of cooling
Deactivates the cooling function.
0 = activated
1 = deactivated
Standard: 0
030
Operating lock
Protects the deactivation of the operating
lock with a PIN.
0 = deactivated
1 = activated
Standard: 0
031
PIN operating lock
Sets the PIN for parameter 30.
0 ... 9999
Standard: 0000
If PIN is unknown:
¾ De-energise the device.
¾ Hold down the rotary control
and apply voltage again until the
software version is shown on the
display and goes out again.
¾ Press the rotary control again until
the symbol
disappears.
If no operation is performed, the display returns to the basic
level after approximately 30 seconds.
¾ Start the entry by activating the function “PAr”.
¾ Select the individual ciphers of the parameter number by rotat-
ing and confirm by pressing.
¾ Activate the entry by selecting “SET” and by pressing.
¾ Perform the setting according to the subsequent parameter list.
¾ Return to the basic level by selecting “BACK” 2 times.