EasyManua.ls Logo

Tecfrigo MEAT 250 - Connection to the Mains; Manual Defrosting

Tecfrigo MEAT 250
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I
UK
D
E
F
NL
P
S
DK
FIN
B
GR
CZ
EE
LV
LT
H
M
PL
SK
SLO
7
Operator'sguide
7.CONNECTIONTOTHEMAINS
1. (A)
2.
3.
4
N.B
5
8.CONTROLS
1.Refrigeration
switch 2.Lightswitch:
3.Thermometer: Thermostat:
a 4 SETorP
n5 UP 6 DOWN
9.CHECKINGCORRECTOPERATION
CHECKTHAT:1. 2
3 4
5.
6.
7
8
9.
10.INTERNAL CLEANING(EVERY 15DAYS)
1. 2.
3 4
5. 6 7
8
11.MANUAL DEFROSTING
1. 2
3
4.
5
12.REPLACINGTHEDOOR'SMAGNETICGASKET
1 2. 3.
Ensurethatmainsvoltageandfrequencyarethesameasthosestatedontheratingplate attached
totheappliance. Ensurethatthesupplysockethasthefollowingcharacteristics:
Ensurethatthereisnodangerofexplosion(AD)
intheroom. . TheconnectingcabletotheapplianceisH05VVF,designedforinternaluse.For
installationinanyotherenvironments,itwillbenecessarytochangethecablewiththeappropriatetype
(forexampleH07VVFforexternaluse). .Ifduringtransportorstoragetheappliancehasbeenplaced
bymistakeinahorizontalpositionorhasbeenturnedupsidedown,leaveforatleastthreehoursinthe
correctpositionbeforeswitchingonthepowersupply. .Connecttheplug(donotusethree-way
adaptersandreductionadapters)(seefigure7).
Thecontrolsoftheappliancearelocatedatthefrontinsideaprotectedrecess.
:toswitchontherefrigerationsystem. toswitchonthelightinsidethedisplay
cabinet. todisplaythetemperatureintheappliance. toadjustthe
temperatureintheappliance. Toadjustthetemperature: )Pressbutton oncetodisplay
thetemperatureset-point,whichcanthenbechangedbypressingbutto orbutton
(seefigure8).
Theplugisconnected. . Therefrigerationunitswitchisswitchedon(greenlighton).
. Thethermometershowsthedesiredtemperatureforthegoodstobestored. . Theinternallightsare
onandthedoorisproperlyclosed. Theapplianceisnotexposedtodirectsunlightortohigh-powered
lamps. Theroomtemperaturedoesnotexceedthatinwhichtheapplianceisdesignedtowork
normally,i.e.+30°C,55%r.h.(climaticclass4). . Thereissuitableclearance(atleast30cm)infrontof
themotorgrilletoensuresufficientairflow. . Thecabinetissuitablyfilled,withoutoverloadingthe
shelves(max.10kgpershelfand40kgperhook)andwithsufficientspaceforcoldaircirculation. The
compressorisonandtheCOMP ledison,iftheinternaltemperatureishigherthanthatsetonthe
thermostat.
Switchofftheelectricitysupply. Removetherefrigeratedgoodsandstoreinasuitablyrefrigerated
place. .Leavethedooropenordefrostcompletely. .Removetheplugfromthebottomofthe
appliance. Donotusepointedmetaltoolstoremovetheicefromtheevaporator. .Drywithcare. .
Leavetheappliancetodrywiththedooropenbeforerestarting. .Emptythedriptrayunderthecabinet
(seefigure9).
Checkforiceandfrostontheevaporatorfins. .Shouldthelayeroffrostbetoothick,andicedripsare
notedthatcouldimpairpassageofair,completedefrostingshouldbeundertaken. .Openthedoorand
removethegoods,leavingthedooropen. Waitfortheicetothawandrefrainfromusingpointedmetal
toolstoremovetheice. .Leavetheappliancetothedrywithdooropenbeforerestarting.
.Openthedoor. Takeholdofthemagneticgasketandpullitoutoftheframe. Insertthenew
gasketandpressitfirmlydownallaround(seefigure10).
a)
b) c)
itisproperly
earthed. Itfulfilstherequirementsoftheratedcurrentassetoutontheratingplate. Itcomplies
withtheIECregulations:-magnetothermaldifferentialswitchwithIn=nominalvalueasstatedonthe
ratingplate;-DifferentialwithIdsensitivity=30mA.

Related product manuals