8
Model: TX-241; Article No. 5064; 02/2023
Preparation
Requirements for the operation of a photovoltaic system
Permission from the owner or owners' association if you are not the owner yourself
Wieland socket (recommendation), permanent connection or Schuko socket
RCD in the fuse box (standard nowadays)
Socket, better protected outdoors
Electricity meter with backstop or bidirectional meter
ATTENTION!
The following requirements must be met in order to operate a photovoltaic
system.
You must register your photovoltaic system with your responsible grid operator.
In addition, a report must be submitted to the responsible authority (Market Master
Data Register (MaStR)).
You must have ensured that an appropriate and sufficiently dimensioned feed-in
socket is already available.
Meter replacement required: A bi-directional meter must be present or depending
on what your electricity provider specifies. Simple electricity meters are often not
sufficient.
If necessary, the consent of the landlord is required.
If you are unsure, please have the local conditions checked, if necessary, or contact
your network operator for information.
Connecting the micro inverter
The micro inverter is already pre-installed on a solar module in this set It may only be
necessary to connect the solar modules (DC) to the micro inverter. On the AC side,
only the connection with the enclosed connection cable must be made. A Wieland
plug connection is recommended here according to VDE. A Schuko plug connection
with a Schuko socket is also possible.
CAUTION!
Observe all local regulations and restrictions during installation.
CAUTION!
The external protective grounding conductor is connected to the protective
grounding conductor terminal of the micro inverter via AC connection. When
connecting, connect the AC terminal first to ensure grounding of the micro
inverter. Then connect the DC terminals. When disconnecting, disconnect the
AC first by opening the branch circuit breaker but keeping the protective
grounding conductor in the branch circuit breaker connected to the micro
inverter. Then disconnect the DC inputs.
CAUTION!
Do not, under any circumstances, connect the DC input if the AC connection
is not connected.
CAUTION!
Install disconnect devices on the AC side of the micro inverter.