EasyManua.ls Logo

Technibel GRFP 485 R - Outdoor Units

Default Icon
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
1 - 48
1-3. Other Component Specifications
Outdoor Units GRFP255R
MODEL No. Outdoor Unit
Power Transformer
Rated
Primary VAC, Hz
Secondary
Coil resistance WHT WHT : 300
BRN BRN : 2.2
Thermal cut off temperature °C
Thermistor (Coil sensor) : TH7
Resistance K 10°C : 23.7 ± 5 % , 20°C : 6.5 ± 5 %
5°C : 18.8 ± 5 % , 30°C : 4.4 ± 5 %
0°C : 15.0 ± 5 % , 40°C : 3.1 ± 5 %
5°C : 12.1 ± 5 % , 45°C : 2.6 ± 5 %
10°C : 9.7 ± 5 % , 50°C : 2.1 ± 5 %
Thermistor (Discharge gas sensor) : TH
8
Resistance K 60°C : 13.8 , 90°C : 5.1
70°C : 9.7 , 100°C : 3.8
75°C : 8.2 , 110°C : 2.8
80°C : 7.0 , 120°C : 2.2
85°C : 5.9 , 130°C : 1.7
Relay (Comp. Magnetic Contactor)
Coil rated VAC
Contact rating VAC, A
Coil resistance (at 25°C)
Solenoid coil or 4 way valve
4 way valve
Solenoid coil
GRFP255R
230 V, 50 Hz
14 V, 0.4A
PBC - 41E - S4
PTC - 51H - S1
STF-01AJ512D1
04-163 Sanyo-1_p62-95 7/9/04 8:09 PM Page 90

Related product manuals