7-6.Cold Draft Prevention (Heating)
This function controls indoor fan speed so a strong draft of cold air will not blow out before the indoor heat
exchange coil have sufficiently warmed up.
STANDBY lamp on front of the indoor unit lights up when this function is working.
when 10 minutes has elapsed,the fan speed is automatically switched to set speed regardless of indoor heat
exchange coil temperature.
The operation temperature shown as Tcin the chart differ by models.
NOTE
OFF
ON
OFF
Set speed
Indoor fan
Standby lamp
Indoor heat exch.
coil temp. (°C)
Tc
Max. 10minutes
39
MCAV77R5VAA MCAV97R5VAAMCAV127R5VAB
Tc 32°C 33°C 34°C