EasyManuals Logo

Technibel R407C User Manual

Default Icon
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Model Combinations
Combine indoor and outdoor units only as listed below.
COOLING ONLY MODELS R407C
Indoor Units
Outdoor Units
DSAV92C5TA- GRV92C5TA-
GRV92L5TA-
DSAV122C5TA- GRV122C5TA-
GRV122L5TA-
DSAV182C5TA- GRV180C5TA-
GRV180L5TA-
GRV180C7TA-
GRV180L7TA-
DSAV222C5TA- GRV220C5TA-
GRV220C7TA-
GRV220L7TA-
HEAT PUMP MODEL R407C
Indoor Units
Outdoor Units
DSAV92R5TA- GRV92R5TA-
DSAV122R5TA- GRV122R5TA-
DSAV182R5TA- GRV180R5TA-
GRV180R7TA-
DSAV222R5TA- GRV220R5TA-
GRV220R7TA-
Power Supply:
5:
220 - 240 V ~ 50 Hz
7: 380-400 V - 3N ~ 50 Hz
DRAIN
1
ELBOW
*
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
Low voltage no. 73/23 EEC and 93/68 EEC.
Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC
and 93/68 EEC.
This declaration will become void in case of misuse and/or non
observance though partial of manufacturer's installation and/or
operating instructions.
37.4163.215.0 04/2003
EG
I
F
D
E
INSTALLATION INSTRUCTIONS
- Split system air conditioner -
COOLING ONLY MODELS
OPERA
TING LIMITS
Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature : 32°C D.B. / 23°C W.B.
Minimum conditions
Outdoor temperature : 19°C D.B.*
Room temperature : 19°C D.B. / 14°C W.B.
Model name GRVxxxL
* : 15°C D.B.
HEAT PUMP MODELS
OPERA
TING LIMITS
Cooling Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature : 32°C D.B. / 23°C W.B.
Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature : 19°C D.B. / 14°C W.B.
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature : 27°C D.B.
Heating Minimum conditions
Outdoor temperature : 8°C D.B. / 9°C W.B.
*
Available only for heat pump models.
TAPPING
2
SCREW 3,5 X 13
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS FIGURE Q.TY PARTS FIGURE Q.TY
RAWL PLUG 4
RECEIVER WITH
1
CABLE (5 mt)
REMOTE
1
CONTROL UNIT
AAA ALKALINE
2
BATTERY
TAPPING
2
SCREW 4 X 30
1.Standard screwdriver
2.Phillips head screwdriver
3.Knife or wire stripper
4.Tape measure
5.Level
6.Sabre saw or key hole saw
7.Hacksaw
8. Core bits ø 5
19. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
Tools required for installation (not supplied)