23TouchScreen TCA 400 Getting Started Guide – Installation
Using key fob, system can be armed in Arm Away
mode and Arm Stay mode. Exit Delay period works
the same way as non-remote arming.
Length of time after an alarm sounds for the
subscriber to enter a valid keypad code to prevent
alarm from being sent to the central monitoring
station.
System is disarmed by entering a valid keypad
code on the touchscreen or a key pad. If an invalid
keypad code is entered, the alarm restarts.
If system is disarmed with within the Abort Window,
no alarm transmission occurs. Contacts can opt not
to receive SMS and/or email messages notifying
them when an alarm was aborted and that the
central monitoring station was not notied.
For ve minutes after the end of the Abort Window
the subscriber can disarm the system to send an
Alarm Cancel tothe central monitoring station.
This feature is not
congurable.
Default: 30 seconds Range:
Minimum is 15 seconds and
the maximum is 45 seconds
This feature is not
congurable.
By default, Verify contacts
are notied by SMS and
email when an alarm is
disarmed during the Alarm
Transmission Delay period.
This feature is not
congurable.
Remote Arming
Abort Window
Disarming
During the
Abort Window
Aborting
Cancel Window
Must be unique and created by the user.
Two security zones that only trip alarm if they are
both faulted within congured period of time. Can
only be created after the security zones have been
added in a separate step.
After Touchscreen has sent an alarm the set
number of times (trips) to the central monitoring
station, no more alarms are sent to the central
monitoring station for 48 hours or until the security
system is disarmed.
Default Duress Code: Null
Default: 10 seconds
Range: 1 second to 999
seconds
Default: 2 trip
Range: 1 to 6 trips
Duress Code
Cross Zoning
Swinger
Shutdown
A four-digit code that immediately sends a silent
alarm when used to arm/disarm the system or
access security settings. Otherwise, this works the
same as the Master keypad code. Alarms sent from
use of the Duress Feature are not recorded in the
touchscreen history, however, they do appear in the
history on the Management Portal.
Default: Duress Code is
disabled.
Use of Duress
Feature
When enabled, the central monitoring station only
contacts the authorities when multiple smoke
detectors are faulted OR one detector is in an
alarm for 60 seconds.
Touchscreen connects to the central monitoring station over broadband and cellular,
no call waiting alert is required.
Perform the system test as described in the XFINITY Home – Secure System Installation
Guide.
Test the security system to ensure that it is in proper communication with the central
monitoring station as described in the XFINITY Home – Secure System Installation
Guide.
Default: DisabledFire Alarm
Verication
Call Waiting
System Test
Communi-
cations