Model 210 Valve (I / O / S) Manual Service and Maintenance
Figure 3 – Tubing Removal
If the solenoids are to be disassembled, inspect the solenoid elastomers for any
“chunking” or missing elastomer pieces. If abnormal wear is visible, the solenoid
should be rebuilt or replaced.
Figure 4 – Solenoid Elastomer Damage Example
Remove the junction box and junction box bracket.
Once the valve cover has clearance to be removed, using an open ended wrench or
socket, remove all of the cover nuts.