21
IN key
OUT/+ key
ALM/DATE key
SET key
SNOOZE/CH key
DCF reception is done twice daily at 02:00 and 03:00 am. If the reception is not successful at
03:00 am, then the next reception takes place the next hour and so on until 06:00am, or until
the reception is successful. If the reception is not successful at 06:00 am, then the next
attempt will take place the next day at 02:00 am.
Once the outdoor data reception test period is completed, the DCF tower icon in the clock
display will start flashing in the upper left corner. This indicates that the clock has detected
that there is a radio signal present and is trying to receive it. When the time code is received,
the DCF tower becomes permanently lit and the time will be displayed.
If the tower icon flashes, but does not set the time or the DCF tower does not appear at all,
then please take note of the following:
Recommended distance to any interfering sources like computer monitors or TV sets is
a minimum of 1.5 - 2 meters.
Within ferro-concrete rooms (basements, superstructures), the received signal is
naturally weakened. In extreme cases, please place the unit close to a window and/ or
point its front or back towards the Frankfurt transmitter.
During nighttime, the atmospheric disturbances are usually less severe and reception
is possible in most cases. A single daily reception is adequate to keep the accuracy
deviation below 1 second.
FUNCTION KEYS:
Weather Station:
The Weather Station has 5 easy to use function keys:
SET key
Press and hold the key to enter manual setting modes: LCD contrast, time zone, time
reception ON/OFF, 12/24 hour display, manual time setting, calendar, temperature
°C/°F, pressure hPa/inHg, relative pressure value, and weather icon sensitivity setting
Reset all MIN/MAX records
Stop the alarm during alarm ringing
Stop snooze mode
Back-light on
ALM/DATE key
Press and hold key for 3 seconds to enter the alarm setting mode
Active/de-active the alarm time
Stop the alarm during alarm ringing
Stop snooze mode
Display date
Back-light on
IN key
Press to toggle between MAX/MIN and current indoor temperature/humidity data
Press to set the alarm hour (inside alarm setting mode)
Decrease relative pressure value (within manual set mode)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technoline WS 9032 and is the answer not in the manual?

Technoline WS 9032 Specifications

Temperature and Humidity IconTemperature and Humidity
indoor temperature measuring range-9.9ºC to +59.9ºC
indoor temperature resolution0.1°C
outdoor temperature measuring range-39.9ºC to +59.9ºC
outdoor temperature resolution0.1°C
indoor humidity range1% to 99%
indoor humidity resolution1%
outdoor humidity range1% to 99%
outdoor humidity resolution1%
Data Checking Intervals IconData Checking Intervals
indoor temperature checking intervalEvery 15 seconds
humidity checking intervalEvery 20 seconds
air pressure checking intervalEvery 15 seconds
outdoor temperature and humidity checking intervalEvery 4 seconds
Transmission and Power IconTransmission and Power
transmission rangeup to 100 meters
weather station power consumption3 x AA, IEC LR6, 1.5V
thermo-hygro transmitter power consumption2 x AA, IEC LR6, 1.5V
battery lifeup to 24 months
Dimensions IconDimensions
weather station dimensions117.4 x 31.2 x 227.1mm
thermo-hygro transmitter dimensions57.3 x 62 x 135.6 mm

Related product manuals