26
1. Use the OUT/+ key to toggle between “hPa” or “inHg” unit
2. Confirm with the SET key and enter the Relative air pressure value setting.
Note: Units of weather icon sensitivity and air pressure history are not affected. They are
always expressed in hPa.
RELATIVE AIR PRESSURE VALUE SETTING
The default relative pressure value is 1013 hPa (29.92 inHg). This can be manually set to
another value within the range of 960 – 1040 hPa (28.35 – 30.72 inHg) for a better reference.
1. The current relative pressure value will start flashing
2. Use the OUT/+ key to increment and IN key to decrement the value. Keep holding the
key allows the value to advance faster.
3. Confirm with the SET key and enter the Weather forecast icon sensitivity setting.
WEATHER FORECASTING ICON SENSITIVITY SETTING:
For locations with rapid changes of weather conditions, the weather icons sensitivity can be
set to a different level for faster display of weather conditions.
1. The current sensitivity value will start flashing.
2. Use the OUT/+ key to set the weather sensitivity level. There are 3 levels of setting: 2,
3 and 4. The value corresponds to the change of air pressure in hPa before the
weather icon will switch to another state. Level 2 is the most sensitive setting, level 4 is
the slowest recording setting (default setting is "3").
3. Confirm with the SET key and exit the Manual settings.
TO EXIT THE MANUAL SETTING MODE
To exit the manual setting mode anytime during the manual setting, press the SNOOZE/CH
key or wait for automatic timeout. The mode will return to normal time display.
ALARM SETTING:
Alarm icons
Alarm time
Flashing
Flashing

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technoline WS 9032 and is the answer not in the manual?

Technoline WS 9032 Specifications

Temperature and Humidity IconTemperature and Humidity
indoor temperature measuring range-9.9ºC to +59.9ºC
indoor temperature resolution0.1°C
outdoor temperature measuring range-39.9ºC to +59.9ºC
outdoor temperature resolution0.1°C
indoor humidity range1% to 99%
indoor humidity resolution1%
outdoor humidity range1% to 99%
outdoor humidity resolution1%
Data Checking Intervals IconData Checking Intervals
indoor temperature checking intervalEvery 15 seconds
humidity checking intervalEvery 20 seconds
air pressure checking intervalEvery 15 seconds
outdoor temperature and humidity checking intervalEvery 4 seconds
Transmission and Power IconTransmission and Power
transmission rangeup to 100 meters
weather station power consumption3 x AA, IEC LR6, 1.5V
thermo-hygro transmitter power consumption2 x AA, IEC LR6, 1.5V
battery lifeup to 24 months