Installaon and Operang Instrucons
VPS devices
Feel good through warmth from electricity - www.technotherm.de
GB
9. Installaon of Electricity
The device was developed for an electrical voltage of 230 V(nominal) and an alternang current of (AC)
50 Hz. The electrical installaon may only be performed according to the user manual and only by a
qualied Electrician. The device was designed to be used with terminaon and the connecon cable
has to be plugged into an appropriate socket at all mes. (Noce Permanent cables may not be used)
The distance between the receptacle and the device hast to be at least 10cm. The connecon line may
not touch the device at any me.
10. Regulaon
From 01.01.2018, the EU conformity of these devices is addionally linked to the fulllment of the
Ecodesign requirements 2015/1188.
The installaon and commissioning of the devices is only permied in conjuncon with external room
temperature controllers that fulll the following funcons:
electronic room temperature control
and has at least one of the following properes:
room temperature control, with presence detecon
room temperature control, with open window detecon
with distance control opon
with adapve start control
The following room temperature controller systems
RF Receiver together with the TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-Interface
(Art.Nr.750 000 640) or
DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101)
TDI- Thermostat / plus-Thermostat
from Technotherm meet the following requirements and therefore the ErP Direcve:
electronic room temperature control plus week mer (RF/DSM/TDI)
room temperature control, with open window detecon (DSM/plus/TDI)
with distance control opon (DSM/RF)
with adapve start control (DSM/plus/TDI)
Use of the VPS / VP Standard range (without external/internal thermostat control) is only permit-
ted on feet.
Installaon of the receiver and the interfaces see separate instrucons. For customer service - see last
page.
Failure to comply with these requirements will result in the loss of the CE mark.