Feel good through warmth from electricity - www.technotherm.de
GB
Type: VPS
Item Symbol Value Value Item Value
Heat output Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output
P
nom
1000 1200 1500 2000 Wa
manual heat charge control, with integrated thermostat NO
Minimum heat
output (indicave)
P
min
1000 1200 1500 2000 Wa
manual heat charge control with room and/or outdoor tempera-
ture feedback
NO
Maximum con-
nuous heat output
P
max,c
1000 1200 1500 2000 Wa
electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electricity
consumpon
fan assisted heat output NO
At nominal heat
output
el
max
1000 1200 1500 2000 Wa
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
<0,5 <0,5 <0,5 <0,5 Wa
single stage heat output and no room temperature control NO
In standby mode el
SB
<0,5 <0,5 <0,5 <0,5 Wa Two or more manual stages, no room temperature control NO
with mechanic thermostat room temperature control NO
with electronic room temperature control YES
electronic room temperature control plus day mer NO
electronic room temperature control plus week mer NO
Other control opons (mulple selecons possible)
room temperature control, with presence detecon NO
room temperature control, with open window detecon NO
with distance control opon NO
with adapve start control NO
with working me limitaon NO
with black bulb sensor NO
Type: VPS DSM (addional DSM interface oponally necessary)
Item Symbol Value Value Item Value
Heat output Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output
P
nom
1000 1200 1500 2000 Wa
manual heat charge control, with integrated thermostat NO
Minimum heat
output (indicave)
P
min
1000 1200 1500 2000 Wa
manual heat charge control with room and/or outdoor tempera-
ture feedback
NO
Maximum con-
nuous heat output
P
max,c
1000 1200 1500 2000 Wa
electronic heat charge control with room and/or outdoor
temperature feedback
NO
Auxiliary electricity
consumpon
fan assisted heat output NO
At nominal heat
output
el
max
1000 1200 1500 2000 Wa
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
0,8 0,8 0,8 0,8 Wa
single stage heat output and no room temperature control NO
In standby mode el
SB
0,8 0,8 0,8 0,8 Wa Two or more manual stages, no room temperature control NO
with mechanic thermostat room temperature control NO
with electronic room temperature control NO
electronic room temperature control plus day mer NO
electronic room temperature control plus week mer YES
Other control opons (mulple selecons possible)
room temperature control, with presence detecon NO
room temperature control, with open window detecon YES
with distance control opon YES
with adapve start control YES
with working me limitaon NO
with black bulb sensor NO