11.Informaon requirements for electrical local space heaters
Type: VPS RF (addional TPF Thermostat and Eco-Interface oonally necessary) / VPS plus RF plus
Item Symbol Value Value Item Value
Heat output Type of heat input, for electric storage local space heaters only (select one)
Nominal heat
output
P
nom
1000 1200 1500 2000 Wa
manual heat charge control, with integrated thermostat NO NO
Minimum heat
output (indicave)
P
min
1000 1200 1500 2000 Wa
manual heat charge control with room and/or outdoor tempera-
ture feedback
NO NO
Maximum con-
nuous heat output
P
max,c
1000 1200 1500 2000 Wa
electronic heat charge control with room and/or outdoor
temperature feedback
NO NO
Auxiliary electricity
consumpon
fan assisted heat output NO NO
At nominal heat
output
el
max
1000 1200 1500 2000 Wa
Type of heat output/room temperature control (select
one)
At minimum heat
output
el
min
2.0 2.0 2.0 2.0 Wa
single stage heat output and no room temperature control NO NO
In standby mode el
SB
<0,5 <0,5 <0,5 <0,5 Wa Two or more manual stages, no room temperature control NO NO
with mechanic thermostat room temperature control NO NO
with electronic room temperature control NO NO
electronic room temperature control plus day mer NO NO
electronic room temperature control plus week mer YES YES
Other control opons (mulple selecons possible)
room temperature control, with presence detecon NO NO
room temperature control, with open window detecon NO YES
with distance control opon YES YES
with adapve start control NO YES
with working me limitaon NO NO
with black bulb sensor NO NO