Tecnik TRONIK 812 - User Manual

Tecnik TRONIK 812
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USER MANUAL
CF-MTL-2401/6003/42401/42403
www.tecnikchargers.comwww.tecnikchargers.comwww.tecnikchargers.com
T812-UM-201709-ENT812-UM-201709-ENT812-UM-201709-EN
TRONIKTRONIKTRONIK
812812812

Other manuals for Tecnik TRONIK 812

Question and Answer IconNeed help?

Do you have a question about the Tecnik TRONIK 812 and is the answer not in the manual?

Summary

Safety Instructions and Warnings

General Safety and Prevention

Covers general safety, shock, burn, and injury prevention measures.

Hazard Prevention and First Aid

Details fire, explosion, arcing prevention, and essential medical/first aid procedures.

Charger Description

Charger Installation

AC Input Wiring Connection

Instructions for connecting the AC input ground and line wires for different models.

AC Input Configuration

How to adjust AC input settings using metal jumpers on terminal blocks.

AC Input Calibration

Procedure for calibrating input tuning according to the AC source via terminal strips.

Using the Charger

Programming Gassing Point

Setting the charger's gassing point voltage using DIP switches on the control board.

Battery Connection and Autostart

Connecting the battery and the automatic starting sequence based on voltage thresholds.

Charge Operation Details

Explains displayed parameters like voltage, current, time, and capacity during charging.

Timers, Data Saving, and Fuses

Covers safety timer termination, automatic data saving during blackouts, and fuse detection.

Charge Termination Procedures

Outlines automatic, automatic shutdown on disconnection, and manual charge termination.

Equalize Functions

Details manual, daily equalize, and auto equalize/refresh modes for battery maintenance.

Refresh Operation

Function to keep batteries in optimal condition during standby by monitoring and re-charging.

Summary

Safety Instructions and Warnings

General Safety and Prevention

Covers general safety, shock, burn, and injury prevention measures.

Hazard Prevention and First Aid

Details fire, explosion, arcing prevention, and essential medical/first aid procedures.

Charger Description

Charger Installation

AC Input Wiring Connection

Instructions for connecting the AC input ground and line wires for different models.

AC Input Configuration

How to adjust AC input settings using metal jumpers on terminal blocks.

AC Input Calibration

Procedure for calibrating input tuning according to the AC source via terminal strips.

Using the Charger

Programming Gassing Point

Setting the charger's gassing point voltage using DIP switches on the control board.

Battery Connection and Autostart

Connecting the battery and the automatic starting sequence based on voltage thresholds.

Charge Operation Details

Explains displayed parameters like voltage, current, time, and capacity during charging.

Timers, Data Saving, and Fuses

Covers safety timer termination, automatic data saving during blackouts, and fuse detection.

Charge Termination Procedures

Outlines automatic, automatic shutdown on disconnection, and manual charge termination.

Equalize Functions

Details manual, daily equalize, and auto equalize/refresh modes for battery maintenance.

Refresh Operation

Function to keep batteries in optimal condition during standby by monitoring and re-charging.

Overview

The TRONIK 812 is a battery charger designed for lead-acid batteries, converting AC input to DC output with a Wa type charge curve. Its operation is managed by the MTL digital charge controller, a microprocessor-based electronic board.

Function Description:

The primary function of the TRONIK 812 is to charge lead-acid batteries automatically. It offers a comprehensive charging cycle with various features to ensure optimal battery health and safety. The charger monitors the entire charging curve and incorporates several safety mechanisms.

Important Technical Specifications:

  • Charge Curve: Wa type.
  • Controller: MTL digital charge controller, microprocessor-based.
  • Operating Temperature: 5°C to 45°C.
  • Storage Temperature: -20°C to 60°C.
  • Relative Humidity: Less than 75%.
  • Input Voltage Configuration: Multi-input chargers (CF-MTL-42401, CF-MTL-42403) allow adjustment via metal jumpers on terminal blocks.
    • CF-MTL-42401: 208/240V, 480V.
    • CF-MTL-42403: 208/240V, 480V.
  • Input Tuning Calibration:
    • CF-MTL-2401: 220V, 240V, 250V.
    • CF-MTL-42401: 208/452V, 225/480V, 240/506V.
    • CF-MTL-42403: 208/452V, 225/480V, 240/506V.
    • CF-MTL-6003: 575V, 600V, 610V.
  • Gassing Point Programming: Adjustable via DIP switches (DS1-SW2 and DS1-SW3) on the MTL control board. Default value is 2.40 Volt/cell. Options include 2.35V, 2.38V, 2.40V, 2.45V.
  • Minimum Battery Voltage for Start: 1.62 V/cell.
  • Maximum Battery Voltage for Start: 2.60 V/cell.
  • Maximum Charging Threshold: 2.80 V/cell.
  • Safety Timer: 12 hours to reach gassing voltage.
  • Equalization Cycles: 5 additional charge cycles of 30 minutes each, with 14 hours and 30 minutes interval between cycles (Auto Equalize and Refresh mode).
  • Display: 4-digit digital display on the front panel.

Usage Features:

  • Automatic Operation: The charger is programmed to execute a complete charge cycle automatically.
  • Battery Connection and Autostart: Connect the battery, and the charger will display the battery voltage. If the voltage is within acceptable limits (1.62 V/cell to 2.60 V/cell), it will wait 3 seconds and then start charging, displaying the programmed gassing voltage.
  • Error Messages:
    • "V LO": Battery voltage below 1.62 V/cell.
    • "V HI": Battery voltage above 2.60 V/cell (at start) or 2.80 V/cell (during charge).
    • "t.Err": Safety timer activated (gassing voltage not reached in 12 hours).
    • "b.Out": AC input black-out.
    • "FUSE": Blown DC output fuse or absent fuse.
  • Charge Operation Display: During charge, the display cycles through:
    • Battery Voltage (V/cell).
    • Charge Current (Amps).
    • Charge Time (Hours.Minutes/tens, e.g., 3.4h for 3h 40min).
    • Capacity Returned (Amp/hours).
  • Proportional Algorithm: Calculates charge time based on the time taken to reach gassing voltage. The final charge continues for half the time needed to reach gassing voltage, with a minimum total time of 30 minutes and a maximum of 5h 59m59s. This allows use with batteries of different capacities without manual adjustments.
  • Automatic Data Saving: In case of AC input black-outs, the microprocessor saves all relevant charging cycle data and restarts automatically from the point of interruption when power is restored.
  • Automatic Charge Termination: The charger shuts down when the charge is complete, displaying "End ELAPSEd x.x h" (time elapsed after termination).
  • Automatic Shutdown on Battery Disconnection: If the battery is disconnected during charge, the charger switches off automatically.
  • Manual Charge Termination: Pressing the red "MANUAL STOP" button on the front panel terminates the charge, displaying "STOP". This disables equalization and refresh functions.
  • Manual Equalize: Activated by pushing the "MANUAL-EQUALIZE" button during the first minutes of charge. Extends the charge cycle by 4 hours, displaying "Eq.On".
  • Daily Equalize: Extends all charge cycles by 4 hours. Useful for recovering highly sulphated batteries. Enabled by moving dipswitch DS1-SW1 to the ON position. Disabled by default.
  • Automatic Equalize and Refresh: Managed by the MTL control. After regular charge, adds 5 additional 30-minute charge cycles with 14.5-hour intervals. Enabled by moving dipswitch DS1-SW4 to the ON position. Enabled by default. During intervals, "End ELAPSEd x.x h" is shown; during cycles, "EqUAL ChArGInG" and current are shown.
  • Refresh Operation (Voltage Control): Keeps the battery in optimal condition during extended standby. The charger monitors battery voltage and automatically activates an extra charge cycle if the voltage drops below a predefined minimum threshold. The display shows "VoLt COntrOL" during monitoring and "rEFrESh" during an extra charge cycle.

Maintenance Features:

  • Safety Instructions: Emphasizes the importance of grounding, proper wiring, and avoiding damp conditions to prevent electric shock.
  • Regular Inspection: Inspect charging leads for damage.
  • Power Disconnect: Always shut off power at the disconnect switch or line breaker before inspection, adjustment, or servicing. Lock the switch OPEN or remove fuses.
  • Cleanliness: Keep inside parts clean and dry to prevent insulation failure.
  • Service Calls: If "t.Err" appears, it's recommended to call TECNIK's service department for a system check.
  • Qualified Personnel: Installation, use, and service should only be performed by qualified personnel.
  • Ventilation: Ensure adequate ventilation in the battery recharging area to prevent hydrogen gas accumulation.
  • Connector Care: Ensure the charger is OFF before connecting or disconnecting the battery to prevent arcing and burning of contacts.

Tecnik TRONIK 812 Specifications

General IconGeneral
BrandTecnik
ModelTRONIK 812
CategoryBattery Charger
LanguageEnglish