IST-2293.PM02.01/B Istruzione / User’s Manual / Manuel d’utilisation Pag.1/10
(IST-2293.PM02.01-B_TS293PM.doc - 15.04.2011)
Trasmettitore di Gas infiammabili con uscita 4÷20mA
Flammable Gas Detector with 4÷20mA output
Sonde a transmetteur 4÷20mA pour gaz inflammables
TECNOCONTROL S.r.l. - Via Miglioli, 47 20090 SEGRATE (MI) Tel. 02/26922890 - Fax 02/2133734
http: www.tecnocontrol.it e-mail: info@tecnocontrol.it
TS293PM
Leggere Attentamente e Conservare quest’Istruzione.
Please read and keep this manual
Lire avec soin et garder la notice d’istruction
Marcatura ATEX / Ex marking / Marquage ATEX
II 2G Ex d IIC T6 Gb
Numero di Certificazione / Certificate number / numéro du certificat
CESI 03 ATEX 323 X
Modello / Model / Modele Calibrato per / Calibrated for / Tarée pour Cartuccia/Cartridge/Cartouche
TS293PM Metano / Methane / Méthane ZSP05/EX
TS293PG GPL / LPG / GPL ZSP05/EX
TS293PI Idrogeno / Hydrogen / Hydrogène ZSP05/EX
TS293PB Benzina / Petrol / Essence ZSP05/EX
TS293PX Vedi Tabella 3 / seeTable 3 / Tableau 3 ZSP05/EX
Con Cartuccia Sensore Sostituibile
Inside Replaceable Cartridge Sensor / Avec Cartouche Capteur échangeable
Caratteristiche tecniche / Technical specifications / Caractéristiques techniques
Alimentazione / Power supply / Alimentation
12÷24Vcc (-10/+15%) 2W
12÷24Vdc(-10/+15%) 2W / 12÷24Vcc(-10/+15%) 2W
Sensore / Sensor Type / Capteur
Catalitico Pellistor /
Catalytic Pellistor / Catalytique Pellistor
Cartuccia Sensore / Cartridge Sensor / Cartouche capteur Sostituibile / Replaceable / échangeable
Uscite / Outputs / Sortie 4 ÷ 20 mA lineare / Linear / linéaire
Resistenza di carico / load resistor / résistance de charge 50 ohm / 12Vdc (-10%) - 500 ohm / 24Vdc (-10%)
Campo di misura / Standard Range / Champ de mesure 0 ÷ 100 % LIE / LEL
Limite Scala / Limits / Limite échelle 100 % LIE / LEL
Vita media in aria pulita / Average Life in fresh air / Vie moyenne en air pur 5 anni / years / ans
Tempo di risposta / Response Time /
Temps de réponse T
90
< 60 secondi / seconds / secondes
Ripetibilità / Repeatability / Répétitivité
5% del segnale / signal
Precisione / Accuracy / Précision ± 2% LIE / LEL
Linearità / Linearity / Linéairite Fino al / up to / jusqu'à 60% LIE / LEL
Deriva a lungo termine in aria pulita
Long time drift in fresh air / Dérive à long terme en air pur
< ± 5 % LIE anno /
LEL year / LIE/an
Tempo massimo di immagazzinamento
Max Storage Time / Temps maximum de stockage
12 mesi / 12 month / 12 mois
Temp./umidità di immagazzinamento / Storage Temp-Humidity
Température et hygrométrie de stockage
-20 ÷ + 55°C / 5 ÷ 95 % RH
non condensata / non condensed / non condensée
Temp./umidità di funzionamento / Operation Temp./Humidity
Température et hygrométrie de fonctionnement
-10 ÷ + 50 °C / 10÷90 % RH
non condensata / non condensed / non condensée
Pressione / Operation Pressure / Pression de fonctionnement Atmosferica / Atmospheric/ Atmosphérique ±10%
Dimensioni - Peso / Size- Weight / Dimensions du boîtier - poids 190 x 105 x 83 mm / 1 Kg
I
DESCRIZIONE ............................................................................................................................ 2
NOTE SUI VARI MODELLI..................................................................................................................... 2
FUNZIONAMENTO................................................................................................................................. 2
INSTALLAZIONE.................................................................................................................................... 2
AVVERTENZE ........................................................................................................................................ 3
VERIFICHE E CALIBRAZIONE.............................................................................................................. 3
GB
DESCRIPTION ............................................................................................................................ 4
NOTES ON THE AVAILABLE MODELS................................................................................................ 4
OPERATIONAL DESCRIPTION............................................................................................................. 4
INSTALLATION ...................................................................................................................................... 5
WARNING............................................................................................................................................... 5
TEST and CALIBRATION ...................................................................................................................... 5
F
DESCRIPTION ............................................................................................................................ 6
MODÈLES............................................................................................................................................... 6
FONCTIONNEMENT .............................................................................................................................. 7
INSTALLATION ...................................................................................................................................... 7
INSTRUCTIONS ..................................................................................................................................... 8
VÉRIFICATIONS ET ETALONNAGE .....................................................................................................8