O P E R A T I N G IN S T R U C T I O NS
Airflow direction control
Adjust the air flow direction properly otherwise it
might cause discomfor t or cause uneven room
temperatures.
Adjust the horizontal/vertical louver using the remote
controller. For some models, the vertical louver can
only be adjusted manually.
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow direction.
The horizontal louver changes 6 degree in angle
for each press, or swing up and down automatically.
Please refer to the <<REMOTE CONTROL MANUAL>>
To set the horizontal/vertical air flow direction
for details.
For some
models, the vertical louver can only be adjusted
manually. Move the deflector rod manually to adjust the air
flow in the direction you prefer.
IMPORTANT: Do not put your fingers into the panel of
blower and suction side.
The high-speed fan inside may
cause danger.
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the h orizontal louver causing
moisture to drop on to the floor or on furnishings.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATIN
G performance may
be impaired due to too restricted air flow area.
Do not move th e horizontal louver m
anually, othe
rwise
the horizontal louver will be out of sync. Please cease
operating, unplug power for a few seconds,then restart
the air condition er.
Do not operate unit with horizontal louver in closed
position.
CAUTION
O P E R A T I N G I N ST R U C T I O NS
NOTE: This manual does not include Remote Contr oller Operations, see the
<<Remote Contr oller Instruction>> packed with the unit for details.
Manual operation
Operating temperature
Mo de
Temperature
Room temperature
Outdoor temperature
1. Optimum performance will be achieved within these operating temperatures.If air
conditioner is used outside of the above conditions, certain safety protection features
might come into operation and cause the unit to function abnormally.
2. If the air conditio ner runs for a long time in cooling mode and the humidity is high(over
80%) , condensed water may drip out of the unit. Please se
ts the vertical air flo w louver to
its maximum angle (vertically to the floor) , and set HIGH fan mode.
NOTE:
Cooling operation
Heating operation
Drying operation
1. Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
For some models, please use suspension
bars to prop up the panel.
2. Locate the MANUAL CONTROL BUTTON
on the right hand side of the unit.
3. Press MANUAL CONTROL BUTTON once
to activate FORCED AUTO mode.
4. Press MANUAL CONTROL BUTTON again
to activate FORCED COOLING mode.
5. Press MANUAL CONTROL BUTTON third
time to turn the unit off.
6. Close the panel firmly to its original position.
NO TE: The un it mus t be turned off before
ope rating the manual control button. If the
unit is o peration al, continue pressing the
man ual control button until the unit is off.
17 C~32 C
(62 F~90 F)
O O
O O
0 C~30 C
(32 F~86 F)
O O
O O
10 C~32 C
(50 F ~90 F)
O O
O O
Uni ts are equipp ed with a switch to run emergency operation mode. It can be accessed by
opening the front panel. This switch is used for manual operation in case the remote controller
fails to work or maintenance necessary.
0
o
C~50
o
C
(32
o
F~122
o
F)
0
o
C~50
o
C
(32
o
F~122
o
F)
-15
o
C~30
o
C
(5
o
F~86
o
F)
Manual control
button
C A U T I O N: This switch is used for testing
purposes only. Please do not use the function
unless is absolutely necessary.
To restore the
remote controller operation, use the remote
controller directly.