WIRING CONNECTION
Power supply
1
Phase
2
Neutral
Relay repeat alarm (optional)
3 Normaly closed(NC)
NC= connectors nos. 3 + connectors nos. 5
NO= connectors nos. 4 + connectors nos. 5
4 Normaly open (NO)
5 Common (C)
6, 7
Not used
Level probe
8
level alarm with stopped pump connectors nos. 9 + connectors nos. 8
level alarm with pump not stopped connectors nos. 10 + connectors nos. 8
9 lev
10 preall
External Signal
11 -
Imput frequency signal (WATER METER PULSE SENDER) connectors nos.
12 + connectors nos. 11
Imput current signal connectors nos. 13 (pole +) + connectors nos. 11 (pole -)
12 +
13 +
6
4
3
1
2
9
8
10
7
5
13
12
11