Tektronix 576 - Section 5 Performance Check;Calibration

Tektronix 576
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S
E
CTIO
N
5
PERF
O
RM
A
N
C
E
C
HE
C
K
/CA
L
I
BR
ATIO
N
General
C
h
ange
information,
if
any,
affecti
ng
t
h
is
section
will
befoun
dat
t
h
e
rear
of
t
h
e
manual
.
T
h
is
combine
d
performance
c
h
ec
k
and
calibration
p
roce-
d
ure provides
bot
h α
met
h
od
of
com
p
aring
t
he
instrument
to
p
erformance
requirements
given
in
t
he
Specification
section
an
d α
met
h
od
of
a
d
j
usting
any
instrument
c
h
aracteristics
w
h
ic
h do not
meet
t
h
is
s
p
ecification
.
Α
performance
ch
ec
k
an
d
calibration recor
d
is
incl
u
d
ed
at
t
h
e
beginning
of
t
h
e
p
roced
ure
for
use
as
α
check
list
to
verify
co
r
rect
calibration
an
d
o
p
eration of
t
he
Ty
p
e
576
or as α
gui
de
for
q
uic
k
calibration
by
an
experience
d
calibrator
.
T
h
e
Ty
p
e
576
s
h
oul
d
be
checke
d
an
d
recalibrate
d
afte
r
eac
h
1000
h
ours
of
operation
orat
least
once
every
6
mont
h
s
to
ensure
t
h
at
it
is
operating prop
erly
.
In
add
ition,
portions
of
t
he
instrument
will
require
recalibrationifcom
p
onentsare
re
p
lace
d
or
ot
h
er
elect
r ical
re
p
airs
are
ma
d
e
.
T
h
e
ste
p
by
step
instructions
in
t
h
is
p
r
oce
d
ure
furnis
h
an
ord
erly
approac
h to
t
h
e
isolation
of
possible
malfu
n
ctio
n
s
and
t
hus
serve
as
an
ai
d
in
tro
u
bles
h
ooting
t
he
instrument
.
Any
maintenance
t
h
at
is
known
to
be
nee
d
ed
s
h
oul
d
be
p
erforme
d
before
starting
t
he
calibration
p
roce
dure
.
If
any
troubles
become
a
pp
arent during
calibration,
t
h
ese
also
s
h
oul
d be corrected
before
p
rocee
d
ing
.
Repair
an
d
servicing
informatio
n
is
given
in t
he
M
aintenance
section
.
E
qui
p
ment
R
e
q
uire
d
T
h
e
following
(or
eq
uivalent)
items
of eq
uipment
are
re
qu
i
r
ed
for
α
com
p
lete
calibration
of
t
h
e
Ty
p
e
576
.
T
he
eq
ui
p
ment
is
illustrate
d
in
F
ig
.
5-1
.
If
substit
u
te eq
ui
p
ment
is
used
,
its
accuracy
must
excee
d
t
he tolerances to be
measure
d
by
at
least
4
times
in
or
d
er
to
ma
k
e
an
accurate
measu
r
ement
.
If
t
he tolerance
to
be
measure
d
is
less
t
h
an
1
°/
ο
,
t
he
accuracy
of
t
h
e
test
e
q
ui
p
me
n
t
must
excee
d
t
he tolerance
by
at
least
10
times
.
1
.
Test
oscillosco
p
e,
Te
k
t
r
onix
Ty
p
e
547
with
Ty
pe
W
Differential
Com
p
ara
-
tor
P
lug-In
U
nit
.
M
inim
u
m
alternate
re
qu
irements
:
Ban
d
wi
d
t
h
f r
omDC
to
100
kH
z
;
swee
p
r
ates
f
r
om
0
.2
ms/cm
to 5 μ
s/cm
;
ve
r
tical
d
eflection
factors
from
1
mV
/cm
to
500
m
V
/cm
;
accu
r
acy
of
voltage
measureme
n
t
wit
h in
3°/
ο
;
internal
com
p
arison
voltage p
ro-
vi
de
d
wit
h
accuracy
of 0
.5%
;
AC
an
d
DC
vertical
in
pu
t
cou
p
ling
;
internal
triggering
.
2
.
Ty
pe
576
Calibration F
ixture
(Te
ktronix
P
a
r
t
Νο
.
067-0599-00)
.
3
.
V
ariable
autotransformer
(e
.g .,
General
Rad
io,
V
ariac
Ty
pe
V
J
10
M
T3
W
) .
Minimum
re
q
ui
r
ements
:
Output
voltage
Ty
p
e
576
variable
from
90
to
136
volts
AC
RM
S for
11
5-volt
operation
or
from
180
to
272
volts
AC
RM
S for
230-volt
operation
;
output p
ower
rating
at
least
305
watts
.
If
monitor
voltmeter
is
not
inclu
d
e
d
,
separate
AC
voltmeter
is
re
q
uire
d
.
4
.
DC
voltmeter
(e
.g
.,
F
l
uk
e
M
od
el
801B
d
ifferential
voltmeter
or
suitable
d
igital
voltmeter)
.
M
inimum
re
q
uire-
ments
:
V
oltage
range
from
0
volts
to
250
volts
;
basic
accura-
cy with
in
0
.6%
ο
;
accuracy
with
in
0
.05%
at
-75
volts
.
5
.
DCV
oltmeter-
H
ig
h
V
oltage
(e .g
.,
Tri
p
lett
M
o
d
el
630
NA)
.
Re
q
uirements
:
M
easure
-5000
volts,
accuracy
wit
h
in
3°/
ο
.
6
.
1
Χ
test
probe,
Te
k
tronix
P601
1,
wit
h
BN
C
connec-
to
r
s
.
Te
ktronix P
art
Νο
.
010-0193-00
.
7
.
42
inc
h
coaxial
cable
.
C
h
aracteristic
im
pe
d
ance
ap-
proximately
93
Ω
;
BN
C
con
n
ecto
rs
.
Te
ktronix P
art
Νο
.
012-0075-01
.
8
.
4
inc
h p
atc
h cord
.
Standar
d
banana
p
lugs
at each end
.
9
.
P
lastic
sc
r
ew
d
river
type
ad
j
ustment
tool
.
Te
k
tronix
P
art
Νο
.
003-0000-00
.
10
.
Small
screwdriver
.
PERF
O
RM
A
N
C
E
C
HE
C
K
/CA
L
I
BR
ATIO
N
RE
CO
R
DA
N
D
I
ND
E
X
T
h
e
following
abri
d
ged p
erformance
c
heck
an
d
calibra-
tion
procedure has
been
provi
de
d
for
use
as α
recor
d of
p
erformance
ch
ec
k
an
d/or
calibration
or
as
α guide for
an
experience
d
calibrator
.
It
may
also
serve
as an
in
d
ex
to
locate
α p
articular ste
p
in t
he p
roce
d
ure
.
Ty
pe
576,
Se
r
ial
Νο
.
P
erformance
C
heck/Calibration
Date
C
hec
k
ed
/Cali
b
rate
d
by
P
O
WER
S
UPPL
Y
1
.
A
d
j
ust
-75-
V
olt
Su
pp
ly
P
age
5-5
A
d
j
ust
R721
for
-75
volts
-
10
.375
volts
.
2
.
C
heck
Ot
her P
ower
S
upp
ly
V
oltages
P
age
5-5
See
com
p
lete
proced
ure
for
S p
ecifica-
tions
.