Tektronix KEITHLEY 2450-EC User Manual

Tektronix KEITHLEY 2450-EC
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User’s Manual
077110402 / November 2016
*P077110402*
077110402
Models 2450-EC, 2460-EC, and 2461-EC
Potentiostats and Galvanostats
A Greater Measure of Confidence
www.tek.com/keithley

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Tektronix KEITHLEY 2450-EC and is the answer not in the manual?

Tektronix KEITHLEY 2450-EC Specifications

General IconGeneral
Model2450-EC
Channels1
Display5-inch capacitive touchscreen
ManufacturerTektronix/Keithley
Voltage Range±200 V
Current Range±1 A
ConnectivityGPIB
Measurement Resolution6.5 digits
Voltage Measurement Resolution100 nV

Summary

Safety Precautions

Introduction to the Potentiostat/Galvanostat

Getting Started with the Instrument

Initial setup and configuration of the SMU instrument for electrochemistry tests.

Cable Assembly Details

Description of the electrically-shielded 1m cable assembly for SMU connections.

Connections and Usage Guide

Instructions for connecting the SMU instrument and electrochemical cell using the cable.

Cyclic Voltammetry

Cyclic Voltammetry Test Application Parameters

Specifies the required parameter settings for the Cyclic Voltammetry test.

Running the Cyclic Voltammetry Test

Step-by-step guide to initiating and running the Cyclic Volammetry test.

Configuring Cyclic Voltammetry Scan Parameters

Defines scan rate, potential vertices, and number of cycles for the CV test.

Saving and Viewing Cyclic Voltammetry Test Data

Procedures for saving test results to a flash drive and viewing data.

Open Circuit Potential Measurement

Open Circuit Potential Test Parameters

Parameters for the Open Circuit Potential (OCP) measurement test.

Running the Open Circuit Potential Test

Instructions for starting and executing the OCP measurement test.

Adjusting Open Circuit Potential Measure Settings

Configures potential range, sample count, and sample interval for OCP measurements.

Saving and Viewing Open Circuit Potential Test Data

Saving OCP test data to flash drive and viewing results on the instrument.

Potential Pulse & Square Wave

Potential Pulse & Square Wave Test Parameters

Defines parameters for potential pulse and square wave tests.

Running the Potential Pulse & Square Wave Test

Guide to launching and executing the potential pulse/square wave test.

Configuring Potential Pulse Settings

Adjusts peak/base potential, current range, period, pulse width, and sample time.

Saving and Viewing Potential Pulse Test Data

Saving pulse test data to flash and accessing saved results.

Current Pulse and Square Wave

Current Pulse & Square Wave Test Parameters

Specifies parameters for current pulse and square wave tests.

Running the Current Pulse & Square Wave Test

Steps to start and run the current pulse/square wave test.

Configuring Current Pulse Settings

Sets base/peak current, potential range, period, pulse width, and sample time.

Saving and Viewing Current Pulse Test Data

Saving pulse test data to flash and viewing results.

Chronoamperometry

Chronoamperometry Test Parameters

Parameters for Chronoamperometry test, including step potential and duration.

Running the Chronoamperometry Test

Procedure to start and execute the Chronoamperometry test.

Configuring Chronoamperometry Settings

Sets up number of steps, potential levels, durations, and measurement parameters.

Saving and Viewing Chronoamperometry Test Data

Saving Chronoamperometry data to flash and viewing saved results.

Chronopotentiometry

Chronopotentiometry Test Parameters

Parameters for Chronopotentiometry, including step current and duration.

Running the Chronopotentiometry Test

Guide to starting and running the Chronopotentiometry test.

Configuring Chronopotentiometry Settings

Defines number of steps, current levels, durations, and measurement settings.

Saving and Viewing Chronopotentiometry Test Data

Saving Chronopotentiometry data to flash and accessing results.