Tektronix 576 - Preliminary Procedure Overview

Tektronix 576
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ment
of
t
h
e
Ty
p
e
576
internal
controls
wit
hout α
com
p
lete
performance
ch
ec
k
,
or
(3)
α
com
p
lete
recalib
r
ation
of
t
he
Ty
pe
576,
w
h
ic
h
inclu
d
es
a
d
j
ustme
n
t
of
internal
controls as
well
as
α
com
p
lete
p
erformance ch
ec
k
.
To
perform
any
of
t
he
above
ope
r
ations,
use
one
of
t
h
e
following
met
h
ods
:
P
e
r
formance
C
hec
k
O
n
ly
.
Start
wit
h
t
he
PRELIM
I
NARY
PR
OC
E
D
URE
Performance
C
h
ec
k Only and p
erform
only
t
hose
ste
p
s
wit
h
titles
starting
wit
h
t
h
e
wor
d Ch
ec
k
,
t
h
roug
h
t
h
e
main
proce
d
ure
and
t
he
Performance
C
h
ec
k
an
d
Calib
r
a-
tion
R
ecor
d
.
Ad
j
ustment
Only
.
Start
with
t
h
e
PREL
I
M
I
N
A
R
Y
PR
O-
C
E
D
URF
-Calibration
an
d
p
erform
only
t
h
ose
ste
p
s
wit
h
titles
starting
wit
h
t
he
wor
d
Ad
j
ust,
t
h
roug
h
out
t
he
main
p
roce
d
ure
and
t
he
Perfo
r
mance
C
h
ec
k and
Calibration
R
ec-
or
d
.
T
he
part of an
a
d
j
ust ste
p
involving
t
he
actual
a
d
ju
st-
ment
is
printe
d
in
re
d
.
Cali
b
ratio
n
.
Start
wit
h
t
he
PREL
I
M
I
N
A
R
Y
PR
OC
E-
D
UR
Ε
-Calibration
and
p
erform
all
t
he
ste
p
s
t
h
ro
u
g
h
ou
t
t
he
main
proce
d
ure
or
t
h
e
Calibration
an
d
Performance
C
h
ec
k
R
eco
r
d
.
Wh
en
doi
ng
α
com
p
lete
calib
r
atio
n o
r
α
complete
a
d
j
ust-
ment
of
i
n
ternal
controls of
t
h
e
instr
ument,
t
he
best
overall
pe
r
f
ormance
will
be
obtaine
d
if
each
a
d
j
ustment
is
made
to
t
he
exact
setting,
eve
n
if
t
he
observe
d performance
is
wit
h
in
tolerance
.
Wh
en
doing
only α
partial
ad
j
ustme
n
t,
howeve
r
,
do
not
rea
d
j
ust
any
controls unless
t
he
observe
d
pe
r
formance
is
not
wit
h
in
tolerance
. Ι
η
eit
h
er
case,
do
not
p
reset
any
a
d
j
ust-
ments
unless
t
hey
are
k
nown
to
be
significantly
out
of
ad
ju
stment
or
u
nless
re
p
airs
have
been
ma
d
e
in
t
he
circuit
.
In
t
h
ese instances,
set
t
h
ep
articular
controls to
mid
range
.
Α
picture
of
t
h
e
Ty
p
e
576and
t
h
ee
q
u
i
p
ment
require
d
to
calibrate
it
or
ch
ec
k
its
pe
r
formance
is
given
in
F
ig
.
51
.
F
ollowing
t
h
is
p
ictu
r
e
is
α
com
p
lete
list
of
initial
control
settings
for
t
he
Type
576
and
significant
control
settings
of
t
he
test
i
n
struments
.
Pa
r
tial
lists
of
i
n
itial
control
settingsare
also
provi
de
d
at
vario
u
s
places
in
t
he main
bo
d
y
of
t
he
text
.
Any
control
setting
not
liste
d
in
one
of
t
h
ese
partial
lists
can
be
assume
d
to
be
set
to
t
he
p
osition
as
designate
d
at
t
he
beginni
n
g
of
t
he p
rocedure
.
T
h
ese
control
settings
can be
use
d
no
matter
w
h
ic
h
of
t
he
t
h
ree
p
roce
d
ures
is
to
be
use
d
.
If
ad
j
ustments
an
d
/or
ch
ec
k s
are
ma
d
e without
followi
ng
one
of
t
he
t
h
ree
proce
d
u
r
es,
start
with
t
he
list
of
control
settings
precee
d
ing
t
he
d
esire
d
ad
j
ustment
or
ch
ec
k
and
follow
t
he
se
q
uence
up
to
t
he
d
esire
d
ste
p
,
ma
k
ing
ch
anges
in
control
settings
as
in
d
icate
d
.
PREL
I
M
I
N
A
RY
PR
OC
E
D
URE
P
erformance
C
h
ec
k
Only
P
erformance
C
h
ec
k
/Cali
br
ation-Type
576
1
.
Set
t h
e
L
ine
V
oltage Selector
assembly
switc
h
es
a
nd
t
h
e
60
H
z-50
Hz
switc
h
on
t
he
Ty
p
e
576
rear
panel
in
ac-
cordance
with
t
he
line
voltage
source
to
be
use
d
.
2
.
Connect
t
he
Ty
p
e
576
to
t
h
e
line
voltage
source
.
3
.
R
emove
t
he
Stan
d
ar
d
Test
F
ixture
from
t
he
Ty
p
e
576
an
d
install
t
h
e
Calibration
F
ixture
(Tek
tronix
P
art
Νο
.
067-0599-00)
in
t
he
Ty
p
e
576
.
4
.
Turn
on
t
he
Ty
p
e
576
.
Allow
at
least
5
minuteswarm-
υρ
at
an
ambient
tem
p
e
r
ature
between
0°
C
an
d
+50
°
C
(+32
0
F and
+122
°
F)
before
ma
k
ing
any
c
h
eck
s
.
5
.
Set
t
he con
trols as
s
h
own
at
t
h
e
beginning
of
t
h
e
procedure
and
start
t
he performan
ce
ch
ec
k proced
ure wit
h
ste
p 5
.
Calibration
1
.
R
emove
t
he
side panels
and
t
he
Stan
d
ar
d
Test
F
ixture
from
t
he
Ty
p
e
576
.
2
.
Set
t
h
e
L
ine
V
oltage
Selector
assembly
switc
h
es
and
t
he 60 H
z-50
H
z
switc
h on
t
he
Ty
pe
576
rea
r
p
anel
in
ac-
corda
n
ce
wit
h
t
he
li
ne
voltage
source
to
be
used
.
3
.
Connect
t
h
e
autotransformer
and
ot
h
er test instr
u
-
ments
to
α
suitable
p
ower
source
Connect
t
he
Ty
pe
576
to
t
he
autotransforme
r
ou
t
p
ut
.
4
.
Set
t
he
autotransformer
for
t
he
li
ne
voltage
and
range
c
h
ose
n
on
t
he
Ty
pe
576
L
ine
V
oltage Selector
assembly
.
5
.
Turn
on
t
h
e
autotransformer,
t
he
Ty
p
e
576
a
nd
t
he
test
oscillosco
pe
.
Allow
at
least
5
minutes
warmu
p
at
an
ambient
tem
p
erature
of
+25
0
C
±5
°
C
(+77
°
F
±9
)
F
)
before
ma
k
ing
any
c
h
ec
k
s
or
ad
j
ustments
.
6
.
Connect
t
he
1
Χ
probe
to
ve
r
tical
in
p
ut
Α
of
t
he
test
oscilloscope
.
7
.
Set
t
he
instrument
controls
as
s
h
own
at
t
he
beginning
of
t
he
p
roce
d
ure
a
nd
sta
r
t
t
he
ad
ju
stme
n
t
an
d
calibration
p
roce
du
re
wit
h
ste
p
1
.

Related product manuals