EasyManua.ls Logo

Tektronix 576 - Power Supply Calibration

Tektronix 576
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F
ig
.
5-2
.
L
.
V
.
RE
G
ULAT
O
R
c
ir
c
u
it
boa
r
d
:
Location
o
f
test
points
and
ad
j
u
stments
in
ste
p
s
I
through
3
.
P
O
WER
S
UPPL
Y
1
.
A
d
j
ust
-75
V
olt
Su
pp
ly
α
.
Set
t
h e
Ty
p
e
576
controls
as
s h
own
above
.
b
.
P
osition
t
h
e
instrument
so
t
h
at
t
he L
.
V
.
RE
G
UL
A-
TO
R
circuitboar
d
(left
side
of
instrument)
is
visible
.
c
.
Connect
t
he
negative
lea
d
of
t
he
DC
voltmeter
to
gro
und
,
p
in
Μ
on
t
h
e
L
.
V
.
RE
G
UL
ATO
R
board, (See
F
ig
.
5-2)
.
Con
n
ect
t
h
e
p
ositive
lea
d
to
t
h
e-75
volt
su
pp
ly,
p
in
Κ
.
B
e
sure
t
hep
ola
r
ity
of
t
he
DC
voltmeter
is
set
for
measuring
α
negative
voltage
.
d
C
HE
CK
F
O
R
-DC
V
oltmeter
r
ea
d
ing
of
-75
volts
±0
.375
volts
(±0
.5%)
.
e
.
AD
JU
ST-
R
721,
-75-
V
a
d
j
ustment
(see
F
ig
.
5-2)
if
t h
e
voltage
is
not
correct
.
ΝΟΤΕ
T
h
e
voltage
level
of
t
h
e
-75-volt
su
pp
ly
affects
the
calibration
of
the
entire
i
nstrumen
t
.
Any
ad
j
ustme
n
t
of
R
721
will
pro
b
a
b
ly
re
q
uire
the
rea
dju
stment of
all
oth
er
instrument
ad
j
ustmentsaswell
.
P
erforma
n
ce
C
h
ec
k
/Cali
b
ratio
n
-Ty
p
e
576
f
.
(If
d
oingonly
a
dj
ustste
p
s
d
isconnect
t
h
e
meter
leads
an
d
go
to
step
4)
.
2
.
C
h
ec
k
Ot
h
er
P
ower
Su
pp
ly
Voltages
α
M
ove
t
h
e p
ositive
lea
d
of
t
he
DC
voltmeter
to
t
he
p
ower
su
pp
ly
test
p
oints
(ot
h
er
t
han
-75
volts)
liste
d
in
Table
5-1
.
(C
h
ange
p
olarity
of
voltmeter
for
positive
volt-
ages
.)
b
.
C
HE
CK
FOR-Meter
reading
oft
h
epower
supply
volt-
age wit
h
in
t
he
tolerance
given
in
t
he
accuracy
colum
n
of
Table
5-1
.
c
.
Disconnect
t
h
e
DC
voltmeter
lea
d
s
from
t
he
Ty
p
e
576
.
d
.
Connect
t
h
e
negative
lea
d
of
t
he
H
ig
h
V
oltage
DC
V
oltmeter
to
ground
(pin
Μ
of
t
h
e
L
.
V
.
RE
G
UL
ATO
R
ci
r
c
u
it
boar
d
)
.
Be
sure
t
he
p
olarity
of
t
h
e
meter
is
set for
measuring
α
negative
voltage
.
e
Set
t h
emeter
for
meas
u
ring
-4kV
.
f
.
Connect
t
he p
ositive
lea
d
of
t h e
meter
to
t
he
arm
of
t
he
I
N
T
EN
SITY
control,
R
883
(see
F
ig
.
5-3),
connecte
d to
t
he
w
h
ite
and p
ur
p
le
wire
.
g
.
C
HE
CKF
O
R
-
M
eter
rea
d
ing
of
-4000volts
.
h
.
Disconnect
t
h
e
H
ig
h
V
oltage
DC
V
oltmeter
lea
d
s
from
t
h
e
Type
576
.
3
.
C
h
ec
kP
owerSu
p
ply
R
egulation
α
.
Trigger
t
he
test
oscillosco
pe on
t
he
internal
linesignal
.
b
Connect
t
he
1
Χ
test
p
robe
groun
d
cl
i
p
to
p
in
Μ
on
t
he
L
.
V
.
RE
G
UL
ATO
R
circuit
boar
d
.
Fi
g
.
5-3
.
L
ocation
of
h
ig
h vo
l
tage
test
p
oi
n
ts
on
rig
h
t
side
o
f
i
n
st
r
u
ment
.
5-5

Related product manuals