Tektronix 576 - Page 126

Tektronix 576
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(±10%
of
0
.1
volts)
for
eac
h
p
osition
of
t
he
Com
p
arison
V
oltage
switc
h
.
q
.
Turn
t
he
Ty
pe
576
A
MPL
IT
UD
E
switc
h
an
d
t
h
e
Cali-
bration
F
ixture
Ste
p Generato
r
switc
h
,
toget
h
er,
t
h
roug
h
-
out
t h
eir
ranges
.
r
.
C
HE
CK
F
OR
-Tent
h
ste
p
on
test
oscillosco
p
e
cente
r
h
orizontal
graticule
line
±2
d
ivisions
(±2%
of
total
outp
ut)
.
s
.
F
or
t
h
e
1
mA,
5
μΑ
,
1
V
an
d 2
V
positions,
repeat
p
arts
k
t
h
roug
h ρ
.
26
.
C
h
ec
k
Offset
M
ulti
p
lier
α
.
Set
t
he
followi
ng
Ty
p
e
576
controls
to
:
O
FF
S
E
T
MUL
T
0
.00
O
FF
S
E
T
AID
A
MPL
IT
U
D
E
1
V
ST
EP
MUL
T
.1
Χ
R
elease
d
b
.
Set
t
he
Calib
r
ation
F
ixtu
r
e
Step Generato
r
switc
h
to
1
V
.
c
.
Set
t h
e
following
test
oscilloscope
controls
to
:
M
illivolts/cm
50
V
c
R
ange
+11
Com
p
arison
V
oltage
10
.000
d
.
P
osition
t
h
e
tent
h
step
on
t
he
test
oscillosco
pe
cente
r
ho
r
izontal
graticule
line
.
e
.
Tu
r n t
h
e
Ty
p
e
576
O
FF
S
E
T
MUL
T
control
t
h
roug
h
-
out
its
range
.
f
.
C
HE
C
K F
O
R
-Step
at
test
oscillosco
p
e
center
h
ori-
zon
tal
line
for
eac
h complete
revol
u
tion of
t
he
O
FF
SET
Μ
UL
T
control
.
g
.
Set
t
h
e
Ty
p
e
576
O
FF
SE
T
MUL
T
control
to
10
.00
.
27
.
C
h
ec
k
M
aximum
Curre
n
t
Out
p
ut
in
Current
M
od
e
α
.
Set
t
he
Ty
pe
576
A
MPL
IT
UD
E
switc
h and
t
he
Cali-
bration
F
ixture
Ste
p Generato
r
switc
h
as
s
h
own
in
Table
5-4
.
b
.
Set
t
he
following
test
oscillosco
p
e con
trols
to
:
c
.
F
or
each
grou
p
of
settings
s
h
own
i
n Table
5-4,
p
ress
t
he
Ty
pe
576
Z
ER
OO
FF
SE
T
button
and
ad
ju
st
t
he
test
oscilloscope
M
illivolts/Cm
V
ariable
for
t
h
ree
d ivisions
of
d
eflectio
n
on
t
h
e
Test
oscillosco
pe
C
RT
.
W
it
h
3
divisions
of
d
eflectio
n
,
p
osition
t
he
ze
r
o
ste
p
on
t
he
bottom
h
orizo
n
tal
graticule
line
an
d
p
ress
t
he
Type
576
AID
O
FF
S
ET
bu
tton
.
A
M
PL
IT
U
D
E
Performa
n
ce
C
hec
k
/Calib
r
ation-Ty
p
e
576
d
.
C
HE
CK
F
O
R
-Dis
p
lay
of
ste
p
family
wit
h
te
n
t
h
ste
p
offset
to
t
he
to
p
h
orizo
n
tal
g
r
aticule
line
of
t
h
e
g
r
aticule
.
O
FF
S
ET
TA
BLE
5-4
C
h
ec
k
M
axim
u
m
Cu
rr
e
n
t
i
n
Cu
rr
en
t
M
ode
ι
T
en
t
h
step
s
h
o
ul
d
be
at
least
4
.5
d
i
v
i
sions
from
bottom
horizontal
g
r
atic
u
le line
.
28
.
C
h
ec
k
R
everse
Current
and
V
oltage
L
imits
α
.
Set
t
h
e
following
Ty
pe
576
controls to
:
2
mA
O
PP
OS
E
b
.
Set
t
h
e
Calibration
F
ixt
u
re
Ste
p
Generator
switc
h
to
10
mA
.
c
.
Set
t
he
test
oscillosco
pe
M
illivolts/Cm
switc
h
to
10
.
d
.
C
HE
CK
F
O
R
-Current
limit
between
o
ne and
two
d
ivisions
below
t
h
e
tent
h
ste
p
(see
F
ig
.
5-11
Α
)
.
ΙΒ
1
SEEN
MEN
N
..
.
......
.
.....
:MW
on
0
ONE
MENOMMENNN
OMENS
MONO
MEMESEEMEN
00
MENEM
F
ig
.
5-11
.
T
est
oscillosco
p
e
disp
l
ay of
r
everse
voltage
and
cu
rrent
li
mi
t
:
(
Α
)
r
everse
cu
rrent limit
;
(
Β
)
r
everse voltage
limit
.
5-
1
9
A
MPL
IT
UD
E Ste
p
Ge
ne
r
ator
100
mA'
200
mA
1
mA
2
mA
.1
mA
.2
mA
5
μΑ
10
μΑ
Time/Cm
5
ms
V
c R
ange
0
Μ
ί
l l
ivol
ts/cm
20
I
npu
t
Atten
u
ation
100