EasyManua.ls Logo

Tektronix 576 - Page 14

Tektronix 576
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
O
p
erating
Instructions-Type
576
O
FF
S
E
T
M
UL
T
Cont
r
ol
ST
EP
S
B
utton
P
rovides
PUL
S
ED
ST
EP
S
B
utto
n
s
ST
EP
F
AM
I
LY
Bu
ttons
R
AT
E B
uttons
2-6
O
PP
OS
E
-Allows
zero
ste
p
of
Ste
p
Generator outp
u
t
to
be
offset
as
many
as
10
ste
p
s
below
its
zero
off-
set
level
.
P
rovi
d
es
calibrated
offset
of
ste
p
Gen-
erato
r
outp
ut to
±10
times
AM
PL
I-
T
UD
E
setting
w
hen
eit
h
e
r
O
FF
SET
AID
or
O
FF
S
E
T
O
PP
OS
E button
is
p
r
essed
.
ste
p
s
of
normal du
ration
(ste
p
lasts
for
entire
p
erio
d
of
r
ate
cycle)
.
Allows
Ste
p
Generator
outp
ut
to
be
a
pp
lie
d
to
Device
U
nde
r
Test
for
only
α po
r
tio
n
of
no
r
mal
ste
p d
uration
.
Pu
lse
d
ste
p
s
occu
r
at
p
ea
k
of
Collector
Sup
p
ly
o
u
t
p
u
t
.
300
μ
s-Selects
p
ulse
d
ste
p
s
with
d
uration
of
300
μ
s
.
Collecto
r
Sup-
ply
is
automatically
switc
h
e
d
to
DC
mo
d
e
.
80
μ
s-Selects
pulse
d
ste
p
s
wit
h
d
u
ratio
n of 80
μs
.
Collector
Sup
p
ly
ί
s a
u
tomatically
switc
he
d
to
DC
mo
d
e
.
300
μs an
d
80
μ
s-
Wh
en
buttons
are
p
r
esse
d
toget
h
er,
selects
pu
lsed
ste
p
s
wit
h d
uration
of
300
μs
;
h
ow-
ever,
Collector
Su
pp
ly
is
not
auto-
matically
switc
he
d
to
DC
mo
de
.
Allows
ste
p
s
to
be gene
r
ate
d
in re
p
eti-
tive families
or
one
family
at
α time
.
ON
REP
-
P
rovi
d
es re
p
etitive
Ste
p
Generato
r
outp
ut
.
O
FF
SI
NG
LE
-
Pr
ovi
d
es
one
family
of
ste
p
s
w
h
e
n
ever
button
is
presse
d
.
Once
button
h
as
been p
resse
d
,
Ste
p
Gene
r
ator
is
turne
d
off
until
presse
d
again
or
until
ON
REP
but-
ton
is
pressed
.
Selects
rate
at
w
h
ic
h
ste
ps
are
gene
r
a-
te
d
.
N
O
R
M-
P
rovi
d
es
normal
Ste
p Gen-
erato
r
rate
of
1
Χ
normal
Collector
Su
pp
ly
r
ate
(120
ste
p
s
p
er
secon
d
for
60
H
z
line
fre
q
uency)
.
2X-Provides
rate
of
two
times
nor-
mal
rate
.
.5X-Provides
rate
of
one
h
alf
nor-
mal
r
ate
.
2
Χ
and
.5X-
Wh
en
buttons
a r
e
p
resse
d
toget
h
er,
p
rovi
d
es
normal
rate
but
wit
h
ste
p
transistions
oc-
curing
at
p
ea
k
of
Collector
Su
pp
ly
sweep
.
ST
EP
/O
FF
SE
T
P
O
L
A
R
ITY
IN-
VERT
B
utton
ST
EP
MUL
T
.1
Χ
B
utton
Controls
Te
r
minal
Selector
Switc
h
LEF
T-O
FF-R
IG
HT
Switch
Inte
r
loc
k
Switch
Connectors
A
dap
ter
Connectors
2Χ
and
.5X-Provides normal
rate
but
with
ste
p
transitio
n
s
occur
r
ing
at
p
ea
k
of
Collecto
r
Su
pp
ly
sweep
.
Allows c
h
ange
of
p
olarity
of
Step Gen-
erator
out
p
ut
(from
p
olarity
set
by
P
O
L
A
R
ITY
switch
)
.
P
rovides
0
.1
times
multiplication
of
ste
p
am
p
litu
d
e,
but
does
not
effect
offset
.
Stand
ard
Test
F
ixture
Selects
way
in
w
h
ic
h
Ste
p
Generator
is
a
pp
lie
d
to
Device
U
nder Test
.
In
all
positions
Collector
Su
pp
ly
output
is
connected
to
Collector
terminal
.
EMITTER
GR
O
UN
D
E
D-
E
mitter
of
Device
U
nd
er
Test
is
connecte
d
to
groun
d
.
ST
EP
G
EN
-Ste
p
Gene
r
ator
is
ap
p
lie
d
to base
te
r
minal
of
Device
U
n
d
er
Test
.
N
o
r
mal op-
erating
p
osition
.
OPEN
(O
R
ΕΧΤ
)-
B
ase
te
r
minal
of
Device
Under
Test
op
en
.
Ex-
ternal
signal
a
pp
lie
d
to
ΕΧΤ
B
AS
E
O
R
EMITINPUT
connec-
tor, will
be app
lie
d to
base
ter-
min
al
.
SHOR
T-
B
ase
terminal
of
De-
vice
Und
er
Test
is
s
h
orte
d
to
emitter
terminal
.
B
AS
E
G
R
O
UN
D
E
D-
B
ase
terminal
of
Device
U
n
d
er
Test
is
connecte
d
to
ground
.
Step
Generator
polarity
is
inverted
.
OPEN
(O
R
ΕΧΤ
)-
E
mitter
ter-
minal
of
Device
Un
d
er
Test
is
op
en
.
E
xternal
signal
a
p
plie
d
to
ΕΧΤ
B
AS
E
O
R
EMIT
I
NPU
T
con
nector,
will
be
a
pp
lie
d
to
emitter
terminal
.
STEP
G
EN
-I
n
verte
d
Ste
p Gen-
e
r
ator
out
p
u
t
is
a
pp
lie
d
to
emit-
ter
of
Device
Un
d
er
Test
.
Selects
w
h
ic
h
device
(c
h
oice of
2)
is
to
be
teste
d
,
left
or
rig
h
t
.
E
nables
Collector
Su
pp
ly
w
hen P
rotec-
tive
Box
is
in
p
lace
an
d
li
d
is
close
d
.
Allows
connection
of
various
test
ad
a
p
te
r
s
to
Stan
d
ar
d
Test
F
ixture
.
Connecto
r
s
will
acce
p
t
stan
d
ar
d
size

Related product manuals