EasyManua.ls Logo

Tektronix 576 - Troubleshooting Procedures

Tektronix 576
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sig
n
ifi-
Mu
lti
p
lie
r
I
Tolerance
ca
n
t
R
esis-
Ca
p
aci-
Resis-
Capaci-
Colo
r
F
ig ur es tons to
r
s
Ι
toys
tors
R
esisto
r
an
d
Ca
p
acitor
Colo
r
Co
d
e
10
2
10
2
±2%
±2%
10
3
1
10
3
1
±3%
r±3%
*
F
or ca
p acitance
of
10
pF
o
r
less
.
(DO
a
nd
3
Ο
1
st,
2
d
an
d3
r
d
sig
n
ifica
n
t
fig
ur
es-
;
Ο
-m
u
lti
p
lie
r
;
Ο
-tole
r
an
ce
;
@
-tem
pe
r
at
ur
e
coefficient
.
NOTE
:
(D
a
n
d/o
r
Ο
.
colo
r
co
d
e
fo
r
ca
p
ac
i
to
r
s
dep
e
nd
s
upon
m
a
nu
fact
ur
er
a
n
d
capacitor
ty
pe
.
May
not
be pr
esent
in
some
cases
.
coded
blue or
p
i
nk
-brown-grey-green
in
d
icates
Te
k
tronix
P
art
N
umber
152-0185-00)
.
T
h
e
cat
hode
a
n
d
ano
d
e
en
d
s
of
metal-encase
d d
iodes
can be
i
d
entifie
d by
t
he d
iode
symbol
mar
ked on
t h e
body
.
T
r
a
n
sistor
an
d
Integrate
d
Circuit
L
ea
d
Co
n
figuration
.
F
ig
.
4-2
s
h
ows
t
he
lea
d
configurations
of
t
he
transistors
an
d
integrate
d
circuits
u
se
d
in
t
h
is
instrument
.
T
h
is
view
is
as
seen
from
th
e
bottom
of
t
h
e
d
evice
.
Troubles
h
ooting
Eq
ui
p
ment
T
he
following
eq
ui
p
ment
is
useful
for
troubles
h
ooti
ng
t
he
Ty
p
e
576
:
1
.
Semiconductor
Tester-Some
mea
n
s
of
testing
t
h
e
transistors,
d
io
d
es
an
d
FE
Ts
use
d
in
t
h
is
i
n
strument
is
h
el
p
-
ful
.
Α
transistor-curve
tracer
suc
h
as
t
he
Te
k
t
r
onix
Ty
p
e
576
will
give
t h
e most
com
p
lete
information
.
2
.
DC
V
oltmeter
and
O
h
mmeter-
Α
voltmeter
for
c
h
ec
k
ing
voltages
wit
h
t
h
e
circuit
an
d
an
o
h
mmeter
for
c
h
ec
k
ing
resistors
an
d
d
io
d
es
are
re
q
uire
d
.
F
or
most
a
pp
li-
cations
α
20,000
oh
m/volt
VO
M
ca
n
be
use
d
to
ch
ec
k
volt-
ages
and
resistances,
if
allowances
are
ma
de
for
t
h
e
circuit
Fi
g
.
4-1
.
Color-code
f
o
r r
es
i
sto
r
s
and
ceram
ic
capacitors
.
M
ainte
na
n
ce-Ty
p
e
576
loa
d
i
n
g
of
α
VOM
wh
en
ma
k
ing
voltage
measureme
n
ts
at
h
ig
h
-im
pe
d
ance
p
oi
n
ts
.
3
.
Test
Oscillosco
p
e-
Α
test
oscillosco
pe
is
require
d
to
view
waveforms
at
different
p
oi
n
ts
i
n
t
he
ci
r
cuit
.
An
oscillosco
pe with
DC
to
10
MH
z
fre
q
uency
res
p
onse and 10
m
V
to 10
V
/
d
ivision
vertical
d
eflection
factor
is
suggeste
d
.
Α
10
Χ
probe
s
h
ould
be
used
to
re
duce
circuit
loa
d
ing
.
Troubles
h
ooting
Tec
h
ni
q
ues
T
h
is
troubles
h
ooting
procedure
is
arrange
d
in
an
or
d
er
w
h
ic
h ch
ec
k
s
t
h
e simp
le
trouble
p
ossibilities
before
p
ro-
cceding
wit
h
extencivo
troubles
h
ooti
ng
.
T
h
e
first
few
ch ec
k
s
ens
u
re
p
ro
p
er
connection,
op
eration
and
calibration
.
If
t
h
e
trouble
is
not
locate
d by
t
h
ese
ch
ec
k
s,
t
he
remaining
ste
p
s
ai
d
in
locating
t
he
d
efective
com
ponent
.
Wh
en
the
d
efective
com
p
on
ent
is
locate
d
,
it
s
h
oul
d be
re
p
lace
d
fol-
lowing
t
he
replacement
p
roce
d
ure
given
under
Corrective
M
aintenance
.
1
.
Ch
ec
k
Co
n
t r
ol
Settings
.
Incorrect
control
settings
can
i
nd
icate
α
trouble
t
h
at
d
oes not
exist
.
If
t
h
ere
is
any
q
uestion
about
t
he
correct
function
or
op
eratio
n
of
any
control,
see
t
he
O
p
erating Instructions
sectio
n
of
t
h
is
manual
.
4-
3
Yellow
4
10
4
10
4
±4%
+100%
-0
Green
10
5
10
5
±0
.5%
_-L5
0
/
.
or
0
.5
pF
*
B
l
u
e
~
-
6-
10
8
1
6
V
iolet
Ι
7
1
---
G
r
ay
8
---
10-2
+80%
-20%
or
0
.25
p
F *
Wh
ite
9
---
10-1
±10%
or
1
p
F
*
(
n
on
e)
±20%
±10%
o
r
1
p
F *

Related product manuals