EasyManua.ls Logo

Tektronix 576 - Section 2 Operating Instructions

Tektronix 576
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General
T
h
is
section
of
t
he
instr
u
ction
manual
p
rovi
d
es
informa-
tio
n
necessary for operating
t
he
Ty
p
e
576
and
for
using
it
to
test
va
r
ious
semicond
uctor
d
evices
.
Include
d
are
set
u
p
p
r
ocedu
res,
α
d
escription
of
t
h
e
Type
576
controls
an
d
con
n
ecto
r
s,
α
d
iscussion
of
t
h
e
t
heory
of
t
he
i
n
st
r
ume
n
t,
α
first
time
o
p
eration
p
roce
du
r
e,
a
n
d
general
op
erating
info
r
-
mation
.
Also
i
n
clu
d
ed
is
α
section
d
esc
r
ibing
t
he
use
of
t
he
Ty
p
e
576
for
measu
r
ing
t
he ch
aracte
r
istics
of
various semi-
con
d
ucto
r
d
evices
.
Cooling
S
E
CTIO
N
2
O
PER
A
TI
N
G
I
N
ST
RU
CTIO
N
S
C
h
ange
info
r
mation,
if
any,
affecti
ng
th
is
section
will
b
e found
at
t
h
e
rear
of
t
he
ma
n
ual
.
I
N
ITIA
L
CO
N
SID
ER
ATIONS
T
he
Ty
p
e
576
maintains
α
safe
op
e
r
ating
tem
p
e r
atu
r
e
w
h
en
op
erate
d
in
an
ambient
tem
p
e
r
atu
r
e
of
0
°
C
(122
°
F)
.
A
d
e
q
uate
clearance
on
all
si
d
es
of
t
he
instrume
n
t
s
hou
l
d be p
r
ovide
d
to
ass
u
re
f r
ee
air
flow
a
nd
d
issi
p
atio
n
of
h
eat
away
f r
om
t
h
e
instrument
.
Α
t
h
ermal
cu
tout
in
t
he
instrument
p
r
ovides
t
he
r
mal
p
rotection
by d
isconnecting
t
h
e
p
owe
r
to
t
h
e
i
n
strument
if
t
h
e
i
n
ternal
tem
p
eratu
r
e
excee
d
s α
safe
op
e
r
ating
level
.
Power
is
au
tomatically
resto
r
e
d
w
h
en
t
h
e
tem
p
eratu
r
e
r
et
u
rns
to
α
safe
level
.
It
shou
ld
be
noted
t
h
at
t
he
instrument
will
tur
n
off
un
d
e
r
ce
r
tain
conditions
of
h
ig
h
collector
su
pp
ly
cur
r
ent ou
t
p
ut
or
h
ig
h
ste
p
gene
r
ator
cu
r
rent
Output
even
t
h
oug
h
t
he
inst
r
ume
n
t
is
being
op
erate
d
in
an
ambient
tem
p
erature
w
h
ic
h
is
wit
h
in
t
he
s
p
ecifie
d
r
ange
.
See
footnotes
in
t
h
e
Specification
section
for
furt
h
er
info
r
mation
.
O
p
erating
V
oltage
an
d
F
re
q
uency
T
he
Ty
pe
576
ca
n be ope
r
ate
d
fr
om
eit
h
er
α
115-volt
or
α
230-volt
line
voltage
source
.
T
he
L
I
NE
VO
L
TAG
E
S
E-
LE
CTO
R
assembly,
locate
d
on
t
he
rear
panel,
allows
co
n
-
version
of
t
he
instrument
so
t
h
at
it
may
be o
p
erate
d
from
one
line
voltage
or
t
he
ot
h
er
.
In
a
dd
ition,
t
h
is
assembly
c
h
anges
t
he
connectio
n
s
of
t
h
e
p
ower
transformer
p
rima
r
y
to
allow
selectio
n
of
one
of
t
h
ree
regulating
ranges
(see
Table
2-1)
.
T
he assembly
also includes
t
he
two
line
f
u
ses
.
Wh
en
t
h
e
i
nstrument
is
converte
d
from
115-volt
to
230-volt
ope
r
atio
n
or
vice
versa,
t
h
e assembly
selects
t
he
p
ro
p
er fuse
to
p
r
ovi
de
t
he
correct
p
rotection
for
t
he
inst
r
ument
.
T
h
e
Ty
p
e
576
may
be
ope
r
ate
d
f r
om
eit
he
r
α 50
Hz
or
α
60 Hz
line
f
r
eq
uency
.
In
o
r
der
to
sync
hr
onize
t
h
e
ste
p
ge
ne
r
ato
r
wit
h
t
he
collecto
r
su
p
ply,
t
he
60
H
z-50
Hz
switc
h
,
locate
d
on
t
he
Ty
pe
576
r
ea
r
p
anel
below
the L
I
NE
Ty
pe
576
V
O
L
TAG
ES
ELE
CTO
R
assembly,
must
be
set
to
t
he
posi-
tion
w
h
ic
h
corres
pon
d
s
to
t
he
line
fre
q
uency
being
u
se
d
.
U
se
t
he
following
p
r
oce
d
u
re
to
conve
r
t
t
h
is
instrument
between
line
voltages,
regulating
ranges or
line
fre
que
n
cies
:
1
.
Disconn
ect
t
h
e
inst
r
ument
from
t
he
p
ower
source
.
TA
BLE
2-1
R
egulati
ng
R
anges
F
ig
.
2-1
.
Line
V
o
l
tage
Selector
assembly
an
d
60
H
z
-50
Hz
sw
i
tc
h
on
t
h
e
rear
panel
(s
h
own
wit
h
cover
removed)
.
R
eg
u
lati
ng
R
an
ge
R
an
ge
Selecto
r
115
V
olts
230
V
olts
Switch
P
ositio
n
N
omi
n
al
N
omi
n
al
_
L
O
(switc
h
bar
in
90
to
110
volts
180
to
220
volts
left
h
oles)
Μ
(switc
h
ba
r
in
104
to
126
volts
208
to
252
volts
mi
dd
le
h
oles)
Η
Ι
(switc
h
bar
i
n
112
to
136
volts
224
to
272
volts
rig
h
t
holes)

Related product manuals