Commands Listed in Alphabetical Order
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:RS232C: CONDition
{RXSTArt|RXDATA|RXENDPacke t|RXPARity|TXSTArt|
TXDATA|TXENDPacket|TXPARit y|}
TRIGger:A:BUS:B<x>:RS232C: CONDition?
Arguments
RXSTArt specifies a search based on the RX Start Bit.
RXDATA specifi es a search based on RX Data.
RXENDPacket specifies a search based on the RX End of Packet condition.
RXPARity specifiesasearchbasedontheRXparity.
TXSTArt specifies a search base on the TX Start Bit.
TXDATA specifi es a search based on TX Data.
TXENDPacket specifies a search based on the TX End of Packet condition.
TXPARity specifiesasearchbasedontheTXparity.
TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe
Sets or returns the length of the data string in Bytes for a RS232 Trigger if the
trigger condition i s RXDATA. Applies to bus <x>, where x is the bus number.
Conditions
This command requires a DPO2COMP application module.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:RS232C: RX:DATa:SIZe <NR1>
TRIGger:A:BUS:B<x>:RS232C: RX:DATa:SIZe?
Arguments
<NR1> is the length of the data string in bytes.
TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue
Sets or returns the binary data string for a RS232 trigger if the trigger condition
involves RX. Applies to bus <x>, where x is the bus number.
Conditions
This command requires a
DPO2COMP application module.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-309