Commands Listed in Alphabetical Order
CMEan (cycle me
an) measures the a rithmetic mean over the rst cycle in the
waveform or the rst cycle in the gated region. This measurement is available
onlyonDPOandMSOmodels.
CRMs (cycle rms) measures the true Root Mean Square voltage over the rst
cycle in the waveform or the rst cycle in the gated region. This measurement is
availableonlyonDPOandMSOmodels.
DELay measures the time between the middle reference (default = 50%) amplitude
point of the source waveform and the destination waveform.
FALL measures the time taken for the falling edge of the rst pulse in the
waveform or gated region to fall from a high reference value (default is 90%) to
a low reference value (default is 10%). This measurement is available only on
DPO models.
FREQuency measures the rst cycle in the waveform or gated region. Frequency
is the reciprocal of the period and is measured in hertz (Hz), where 1 Hz = 1
cycle p
er second.
HIGH measures the High reference (100% level, sometimes called Topline) of a
wavef
orm. This measurement is available only on DPO models.
LOW measures the Low reference (0% level, sometimes called Baseline) of a
wavef
orm. This measurement is available only on DPO models.
MAXimum nds the maximum amplitude. This value is the most positive peak
volt
age found. It is measured over the entire waveform or gated region. This
measurement is available only on DPO models.
MEA
N
amplitude measurement nds the arithmetic mean over the entire waveform
or gated region. This measurement is available only on DPO models.
MI
NImum
nds the minimum amplitude. T his value is typically the most negative
peak voltage. It is measured over the entire waveform or gated region. This
measurement is available only on DPO models.
NDUty (negative duty cycle) is the ratio of the negative pulse width to the signal
period, express ed as a percentage. The duty cycle is measured on the rst cycle in
the waveform or gated region.
Negative Duty Cycle = ((Negative Width) / Period) × 100%
NEDGECount is the c ount of falling edges.
NOVershoot (negative overshoot) nds the negative overshoot value over the
entire waveform or gated region. This measurement is available only on DPO
models.
Negative Overshoot = ((Low Minimum) / Amplitude) × 100%)
NPULSECount is the count of negative pulses.
2-192 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix DPO2024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2024 and is the answer not in the manual?

Tektronix DPO2024 Specifications

General IconGeneral
BrandTektronix
ModelDPO2024
CategoryTest Equipment
LanguageEnglish

Related product manuals