Bandwidth | 8 GHz |
---|---|
Channels | 4 |
Vertical Resolution | 8 bits |
Vertical Sensitivity | 1 mV/div to 1 V/div |
Input Impedance | 50 Ω or 1 MΩ |
Input Coupling | DC, AC, GND |
Maximum Input Voltage | 5 Vrms (50 Ω), 400 V (1 MΩ) |
Trigger Modes | Edge, Runt, Setup/Hold, Serial |
Display | 12.1-inch XGA color LCD |
Interface | LAN, USB, GPIB, HDMI |
Operating Temperature | 0 °C to 50 °C |
Timebase Accuracy | ±5 ppm |
Review safety precautions to avoid injury and prevent damage to the product or connected products. Comply with codes.
Additional information for safely performing service. Only qualified personnel should perform service.
Details the EMC (electromagnetic compliance) standards the instrument complies with.
Lists the safety standards with which the product complies.
Highlights the main capabilities and specifications of the MSO/DPO70000/7000/5000B Series instruments.
Specifies the environmental and operational requirements for the instrument.
Provides techniques to prevent electrostatic discharge damage to the instrument input.
Identifies the components and controls located on the front panel of the instrument.
Locates and identifies the connectors and ports on the side and rear panels.
Describes the function of each control on the instrument's front panel.
Procedure to verify the instrument's functionality using internal diagnostics.
Procedure to perform signal path compensation for accurate measurements.
Guides on connecting probes and selecting input channels for signal acquisition.
Procedure to automatically set up the instrument for signal acquisition.
Guidance on optimizing measurement accuracy by compensating and deskewing probes.
How to use FastAcq mode to capture transient events and display phenomena.
Utilizes DSP for accurate rise time measurements and extended bandwidth.
Guides on connecting logic probes and setting up digital channels for signal acquisition.
Details on setting digital channel threshold, size, position, and label.
Procedure to set up serial and parallel buses for triggering and display.
Configuration steps for setting up serial bus parameters.
Configuration steps for setting up parallel bus parameters.
Configure the instrument to save files or send emails when specific events occur.
Procedure to configure and enable email notifications triggered by events.
Details for setting up recipient addresses, SMTP server, and attachments for email alerts.
How to magnify waveforms vertically, horizontally, or in both dimensions.
How to use Wave Inspector controls for efficient work with long record length waveforms.
How to mark locations of interest in acquired waveforms for analysis.
Procedure to select channels and measurements for automatic analysis.
Use cursors to take manual measurements on acquired waveform data.
How to display vertical or horizontal histograms for statistical analysis.
Procedure to use the Serial Error Detector for Bit, Frame, Symbol, and Character tests.
How to compare a signal to a predefined template or mask.
How to compare an active signal with a template waveform for pass/fail testing.
Steps to create custom control windows with regularly used controls.
Example of using FastAcq to find and capture intermittent anomalies in signals.
Procedure for setting up bus triggers on various serial and parallel buses.
Summarizes safety precautions for using the probe.