EasyManua.ls Logo

Tektronix FG 504

Tektronix FG 504
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P
roce
d
ure
NO
ΤΕ
In
t
he
following
p
r
oce
du
r
e,
the
test
oscillosco
p
e
ve
r
tical
i
np
ut
requirements
will
be
identified as
Differential
o
r j
ust
In
pu
t
.
Differential
indicates
a
system
providing
differential
o
p
eration
with
at
least
1
m
V
l
d
ίν
sensitivity
.
Wh
en α
test
oscillosco
pe
is
mentio
ne
d
,
use
α
60
MHz
(or
greater)
system
wit
h
5
m
V
to
5
V
/d
ίν
sensitivity
(200
MHz
for
ste
p
s
12
and
14)
.
1
.
Set
+15
V
Supply
(
R
1605)
Set
t
h
e
digital
voltmeter
ra
n
ge
to 20
V
dc
.
Connect
t
h
e
low
level
test
lea
d
to
t
he
ground
test
p
oi
n
t
on
the
Al
MAIN
board
.
Connect
t
he
h
ig
h
i
npu
t
test
lea
d
to
t
he
+15
V
test
p
oi
n
t
on
t
h
e
Α
1
MAIN
board
.
C
heck
for
α
r
ea
d
i
ng
of
+15
V
±30
m
V
.
If
outsi
d
e
of tolera
n
ce,
a
d
ju st
R1605
(+15
V
Ad
j
)
for
correct
readi
ng
.
NO
ΤΕ
If
R
1605
(ste
p
1)
or
R
1705
(ste
p
2)
settings
requi
r
e
a
dj
ustme
n
t,
t
he
entire
ad
j
ustme
n
t
procedure
m
u
st
be
performed
.
2
.
Set
-15
V
S
u
pply
(
R
1705)
M
ove
t
he
h
ig
h
i
np
ut
test
lead
to
t
he
-15
V
test
p
oint
on
t
he
Α
1
MAIN
boa
r
d
.
C
h
eck
for
α
reading
within
±10
m
V
of
t
he ab
sol
u
te
value
of
t
he
+15
V
su
p
ply
readi
n
g
i
n
ste
p
1
.
If
readi
ng
is
ou
t
of tolera
n
ce,
a
dj
ust
R
1705 (-15
VA
dj)
.
3
.
C
h
ec
kP
owerSupply
V
oltages
M
ove
t
h
e
h
ig
h
i
npu
t
test
lead
to
t
h
e
test
p
oi
n
ts
οη
t
h
e
Α
1
MAIN
boar
d
a
nd
set
t
h
e
voltmete
r
ra
n
ge
switch
as
necessary
w
h
ile
meas
u
ring
t
he
followi
ng su
p
p
lies
for
liste
d
tolera
nce
limits
:
Supply
Tolera
n
ce
+25
V
±0
.5
V
-25
V
+0
.5
V,
-1
.5
V
+5
V
±0
.2
V
4
.
C
h
ec
k
P
ower
Sup
p
ly
R
ip
p
le
an
d Noise
Set
t
h
e
Differential
oscilloscope
Trigger
to
L
i
n
e,
V
e
r-
tical
I
np
ut
Cou
p
ling
to
ac,
an
d
V
ertical
Se
n
sitivity
as
re
q
uired
.
Co
nn
ect
α
1
Χ
probe
to
eac
h
d
ifferential
i
np
ut
.
Connect
t
he
-
(mi
n
us)
input
p
robe
ti
p
to
t
h
e
F
G
504
c
h
assis
grou
n
d
.
Con
n
ect
t
he
+
in
p
ut
probe
ti
p
to
t
he
ap
pr
o
pr
iate test
p
oi
n
ts
on
t
h
e
Α
1
MAIN
board
.
C
heck
ri
p
ple
and
noise
accor
d
i
ng
to
t
h
e
following
table
.
Calibratio
nP
rocedure-
F
G504
(S
NΒ
040000
&
UP)
A
dj
ustme
n
t
Pr
oce
du
re
S
upp
ly
Tole
r
ance
+15
V
Less
t
ha
n
500
μ
V
ρ
-
ρ
-15
V
L
ess
t
han
500
μ
V
ρ
-
ρ
+25
V
Less
t
han 5
mV
ρ
-
ρ
-25
V
Less
t
h
a
n 5
mV
ρ
-
ρ
+5
V
Less
t
h
a
n
100
m
V
ρ
-
ρ
Discon
n
ect
t
h
e p
r
obes
.
5
.
Ad
j
ust
T
r
ia
n
gle
DC
L
evel
(
R
360)
Set
t
he
oscilloscope
vertical
i
npu
t
co
up
li
n
g
to
dc,
volts/
d
iv
to
20
m
V,
variable
volts/div
as
re
q
uired,
time
base
to
0
.5
ms/
d
iv,
trigger
source
to
exter
n
al,
and
trigge
r
mo
de
to
auto
.
Co
n
nect
α 10
Χ
probe
to
t
h
e
oscilloscope
vertical
i
np
ut,
t
h
e
p
robe
grou
n
d
clip
toth
e
F
G
504
c
h
assis
ground
and
t
h
e
probe
tip
to
ΤΡ
1
on
t
he F
G
504
Α
3
L
OO
P
board
.
Co
n
nect
α 50
Ω
coaxial
cable
from
t
he
F
G
504
T
R
IG
O
U
T
PU
T
to
t
he
oscilloscope
external
trigger
i
n
put
co
nn
ector
.
Push
t
h
e
T
R
IGG
ER
FREE
RUN
a
n
d
tria
ngle
p
ush
butto
ns
i
n
.
R
elease
t
he
H
O
L
D/
RUN
bu
tton
to
RUN
(out)
and
set
t
he
MUL
TI
PL
I
ER
to
10'
.
A
dju
st
t
he
os-
cilloscope
for
an
externally
trigge
r
ed
6-
d
ivisio
n d
is
p
lay
.
Set
t
he
oscillosco
p
e
vertical
i
nput
coupling
to
g
r
ound
a
nd
p
ositio
n th
e trace
vertically
to
t
h
e
exact
graticule
center
.
Set
t
he
vertical
i
npu
t
cou
p
li
ng
to
do
a
nd ad
j
ust
R
360
(Triangle
d
o
L
evel)
on
t
h
e
Α
3
L
OO
P
boa
rd
for
tria
n
gle
p
ea
ks e
qu
ally
s
p
ace
d a
b
ove
a
nd
below
graticule
center
.
Disco
nn
ect
t
h
e 10
Χ
p
robe
.
6
.
A
dj
ust
Top
Dial
W
avefo
r
m
Symmetry
(1152)
Co
nn
ect
α
50
Ω
coaxial
ca b
le
from
t
h
e
F
G
504
O
U
T-
PU
T
terminal
to
α 50
Ω
termi
n
atio
n
co
nn
ected
to
t
h
e
oscillosco
p
e
vertical
i
npu
t
.
C
han
ge
t
he
followi
n
g
F
G
504
co
n
trol
setti
ngs
:
Pu
shth
e
square
wave
pus
h
button
in
a
nd
set
t
h
e
FRE
Q
UEN
CY
Hz
(STA
R
T)
dial
to
40
(40
kH
z
square
wave)
.
Set
t
he
oscillosco
p
e
ve
r
tical
for
α 5
V
/div
display
;
set
time/
d
iv,
varia
b
le,
a
nd
triggering
(source
to
Internal
;
level
as
re
q
uire
d
)
so
t
he
n
egative-goi
ng
h
alf-
cycle
of
t
he square
wave
j
ust
fills
t
h
e
graticule
area
h
orizo
n
tally
.
Switc
h
t
he
oscillosco
p
e
trigger
slo
p
e
from
+
to
-
w
h
ile
ad
j
usti
ng R52
(Top
Dial
Sym
Cal)
on
t
h
e
Α
3
L
OO
P
board
so
t
he h
alves
of
t
he
squa
r
e
wave
are
exactly
eq
ual
i
n
time
(
R
52 only
affects
t
he
p
ositive
h
alf)
.
Set
t
h
e
oscilloscope
trigger
slope
to
+
.
7
.
Ad
j
ust
M
inimum
Dial
W
aveform
Symmetry
(
R
155)
C
h
ange
t
h
e
F
G
504
FRE
Q
UEN
CY
Hz
(STA
R
T)
dial
setti
ng
to
α
p
ositio
n
a
pp
roximately
h
alf
way
b
etween
α
.1
and
1
on
t
he
d
ial
and
set
t
h
e
MUL
TI
PL
I
ER
to
10
°
.
Ad
j
ust
t
he
oscillosco
pe
sweep
s
p
ee
d
so
t
h
e
p
ositive
h
alf
of
t
h
e
waveform
cycle
j
ust
fills
t
he
graticule
h
orizo
n
tally
.
Switc
h
t
he
oscilloscope
trigger
slo
pe
from
+
to
-w
h
ile
ad
j
usting
R
155
(
M
in
Dial
Sym
Cal)
on
t
he
Α
3
L
OO
P
board
so
t
h
e
h
alves
of
t
h
e
square
wave
are
exactly
eq
ual
i
n time
(
R
155
only
affects
t
he
n
egative
h
alf
of
t
he
waveform)
.

Related product manuals