Commands Listed in Alphabetical Order
Syntax
DISPlay[:WIND
ow]:TEXT[:DATA] <string>
DISPlay[:WINDow]:TEXT[:DATA]?
Arguments
String with quotes. 48 character length limit.
DISPlay[:WINDow]:TEXT:CLEar (No Query Form)
Clears the characters on the display and then returns the display to normal mode.
Group
Display
Syntax
DISPlay[:WINDow]:TEXT:CLEar
Arguments
None
*ESE
Sets and queries the bits in the Event Status Enable Register (ESER). The ESER
is an eight-bit mask register that determines which bits in the Standard Event
Status Register (SESR) will set the ESB bit in the Status Byte Register (SBR).
(See page 3-1, Status and Events.)
Group
Status
Syntax
*ESE <m ask>
*ESE?
Related Commands
*CLS, *ESR?
Arguments
<mask>::=<NR1> where:
<NR1> is a value in the range from 0 through 255
. T he binary bits of the ESER
are set according to this value.
The power-on default for ESER is 0 if *PSC is 1. If *PSC is 0, the ESER
maintains its value through a power cycle.
Examples
*ESE 145 sets the ESER to binary 10010001, which enables the PON, EXE,
and O PC bits.
2-14 Series 2200 Programmable Multichannel DC Power Supplies Programmer Manual