EasyManuals Logo
Home>Tektronix>Power Supply>KEITHLEY 2200 Series

Tektronix KEITHLEY 2200 Series User Manual

Tektronix KEITHLEY 2200 Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Command Groups
Table2-5: Statuscommands(cont.)
Command Description
STATus:QUEStionable:INSTrument:ISUMmary<x>:CO NDition? Return questionable condition register summary for channel
x, where <x> is 1, 2, or 3. When a bit of the quest condition
changes, the corresponding bit value in the quest event register
will be set to x.
STATus:QUEStionable:ENABle Set/query questionable enable register. This parameter
determines which bit of the quest event register is set to 1. If a
QUES condition changes, the QUES bit of status byte register
will be set to 1.
STATus:QUEStionable[:EVENt]?
Return questionable event register.
STATus:OPERation:INSTrument[:ENABle]? Set/query operation enable register. The parameter determines
which b it value of quest event register is set to 1. If a OPER
condition changes, the O PER bit of the status byte register will
be set to 1.
STATus:OPERation:INSTrument[:EVENt]?
Return operation event register.
STATus:OPERation:INSTrument[:EVENt]? Queries the contents of the operation instrument event register
(OIEVR).
STATus:OPERation:INSTrument[:ENABle]? Queries the contents of the operation instrument enable register
(OIENR).
STATus:OPERation:INSTrument:ISUmmary<x>[:EVENt]? Return operation event register for channel x, where <x> is 1,
2, or 3.
STATus:OPERation:INSTrument:ISUmmary<x>:ENABle Set/query operation enable register for channel x, where <x> is
1, 2, or 3. The parameter determines which bit value of quest
event register is set to 1. If a OPER condition changes, the
OPER bit of the status byte register will be set to 1.
STATus:OPERation:INSTrument:ISUMmary<x>:C ON D ition? Return operation condition register for channel x, where <x> is
1, 2, or 3. When a parameter of the operation condition register
changes, the corresponding bit in the operation event register
will be set to 1.
Save and Recall Commands
Save and recall commands allow you to save the active s ettings to one of the
settings memories within the power supply, and recall those settings at a later time.
Table 2-6: Save and recall commands
Header Description
*SAV Save instrument setting to setup memory
*RCL Recall instrument setting from setup memory
2-8 Series 2200 Programmable Multichannel D C Power Supplies Programmer Manual

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix KEITHLEY 2200 Series and is the answer not in the manual?

Tektronix KEITHLEY 2200 Series Specifications

General IconGeneral
BrandTektronix
ModelKEITHLEY 2200 Series
CategoryPower Supply
LanguageEnglish

Related product manuals