EasyManua.ls Logo

Tektronix KEITHLEY 2200 Series - Page 40

Tektronix KEITHLEY 2200 Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commands Listed in Alphabetical Order
Syntax
[SOURce]:CHAN
nel:OUTPut:[STATe] {0|1|ON|O FF}
[SOURce]:CHANnel:OUTPut:[STATe]? ON
Related Commands
INSTrument:SELect
Arguments
0 or OFF indicates that the channel is off.
1 or ON indicates that the c hannel is on.
Examples
CHANNEL:OUTPUT OFF would turn whichever channel had been selected using
an
INSTRUMENT command to the off state.
CHAN:OUTP? might return 0 to indicate that the current channel is off.
[SOURce:]CURRent[:LEVel]:DOWN[:IMMediate][:AMPLitude] (No Query Form)
This command is used to decrease the current level by a step.
The stepping current can be set by the following command:
[SOURce:]CURRent[:LEVel][:IMMediate]:STEP[:INCRement]
Group
Source
Syntax
[SOURce:]CURRent[:LEVel]:DOWN[:IMMediate][:AMPLitude]
Related Commands
[SOURce:]CURRent[:LEVel][:IMMediate]:
STEP[:INCRement]
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
This command is used to set or query the current value of the power supply in
units of A or mA.
Group
Source
Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
{<Current>|MIN|MAX}
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]?
Related Commands
INSTrument:SELect
2-26 Series 2200 Programmable Multichannel DC Power Supplies Programmer Manual

Related product manuals