Commands Listed in Alphabetical Order
Examples
MATH1:DEFINE "
CH1+CH2"
adds the Ch 1 waveform and Ch 2 waveform,
storing the results in Math 1.
MATH:DEFINE?
might return :MATH1: DEFINE "CH2*REF2" as the expression
that denes Math 1.
MATH[1]:HORizontal:POSition
Sets or returns the math horizontal display position for FFT or (non-live), live
math reference waveforms.
Group
Math
Syntax
MATH[1]:HORizontal:POSiti on <NR
3>
MATH[1]:HORizontal:POSiti on?
Arguments
<NR3> is the % of the math waveform that precedes center screen. It can vary
from 0.0 to 100.0.
Examples
MATH:HORIZONTAL:POSITION 10 sets the horizontal position to 10% pretrigger
MATH[1]:HORizontal:SCAle
Sets or returns the math horizontal display scale for FFT or (non-live), live math
waveforms. The horizontal scale of a dual math waveform w ith a channel source
waveform is set through the HORizontal:SCAle command.
Group
Math
Syntax
MATH[1]:HORizontal:SCAle <NR3>
MATH[1]:HORizontal:SCAle?
Arguments
<NR3> is the math horizontal scale in seconds.
Examples
MATH:HORIZONTAL:SCALE? might return MATH:HORIZONTAL:SC ALE 2.0E-4
indicating that the math horizontal scale is 200 μ
2-180 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix MSO2014

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO2014 and is the answer not in the manual?

Tektronix MSO2014 Specifications

General IconGeneral
BrandTektronix
ModelMSO2014
CategoryTest Equipment
LanguageEnglish

Related product manuals