EasyManuals Logo
Home>Tektronix>Test Equipment>MSO2014

Tektronix MSO2014 Programmer's Manual

Tektronix MSO2014
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #324 background imageLoading...
Page #324 background image
Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:LIN:IDentier:VALue
Sets or returns the binary address string used for LIN trigger if the trigger
condition is ID or IDANDDATA.
Conditions
This command requires a DPO2AUTO application m odule.
Group
Bus
Syntax
TRIGger:A:BUS:B<x>:LIN:ID entifier:VALue <QString>
TRIGger:A:BUS:B<x>:LIN:ID entifier:VALue?
Arguments
<QString> is the binary address string used for LIN trigger if the trigger
condition is ID or IDANDDATA.
Examples
TRIGGER:A:BUS:B1:LIN:IDEN TIFIER:VALUE "110010" sets the identier
value to 110010.
TRIGGER:A:BUS:B1:LIN:IDEN TIFIER:VALUE? might return
TRIGGER:A:BUS:B1:LIN:IDEN TIFIER:VALUE "XXXXXX" indicating that the
identier value is XXXXXX.
TRIGger:A:BUS:B<x>:PARallel:VALue
Sets o
r returns the binary data string to be used for a parallel trigger. Applies to
bus <x>, where x is the bus number.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:PARall el:VALue <QString>
TRIGger:A:BUS:B<x>:PARall el:VALue?
Arguments
<QString> is the binary data string.
TRIGger:A:BUS:B<x>:RS232C:CONDition
Sets or returns the condition for a RS232C trigger, where x is the bus number.
Conditions
This command requires a DPO2COMP application module.
2-308 MSO2000B, DPO2000B, M SO2000 and DPO2000 Series Oscilloscopes Programmer Manual

Other manuals for Tektronix MSO2014

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO2014 and is the answer not in the manual?

Tektronix MSO2014 Specifications

General IconGeneral
BrandTektronix
ModelMSO2014
CategoryTest Equipment
LanguageEnglish

Related product manuals