EasyManuals Logo
Home>Tektronix>Pulse Generator>PG 508

Tektronix PG 508 User Manual

Tektronix PG 508
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
To
u
se
t
h
is
feat ur
e,
p
lace
t
h
e
DD
501
i
n
t
he
d
elay
interval
m
o
d
e
of
o
p
eration
b
y
moving
t
h
e
wi
r
e
st
r
ap
as
s
h
ow
n
i
n
Pig
.
1-5or cha
n
ging
con
n
ectio
n
s,
de
pe
nd
i
ng on
t
he
DD
501
availa
b
le
.
Co
nnectthe
P
G
508
a
n
d
t
he
DD
501
as sh
ow
n
in
F
ig
.
1-6
.
U
se
te
n
i
n
c
h
(Te
k
t r
on
ix
P
art
Nu
m
b
er
012-0208-00)
o
r
sh
orter
cables
forinterconnecting
t
h
etwo
u
nits to
r
ed
uce
d
elays
.
M
ake
certai
n
t
he
PG
508
TRIG/GATE
IN
i
nput im-
p
eda
nce
is
set for
50
Ω
.
(See
E
xternal
Triggering
an
d
Gati
n
g
d
isc
u
ssio
n
an
d
Fig
.
1-2
.)
Set
t
h
e
controls
of
t
h
e
P
G
508
for
t
he
desire
d
output
waveform
wit
h
t
h
eP
G
508
i
n
FREE
R
UN
.
Do
n
ot
use
t
h
e
SQ
W
A
VE
mo
de
.
Place
t
h
e
P
G
508
i
n
t
h
e
-
Ι
-
S
L
O
P
E,
SY
NC
GATE
mode
a
n
d
set
t
h
e
TRIG/GATE
L
EV
E
L
control
at
t
h
e
2
o'clock
p
osition
.
Select
EVENTS
-+-
S
L
O
PE,
STA
RT+
S
L
O
PE
and
place
the
EV
E
N
TS
a
nd
STA
R
T
LEV
E
L
co
n
trols
at
t
h
e
2
o'clock
p
ositio
n
on
t
he
DD
501
.
T
h
e
t
h
ree
TRIG'D
lig
h
ts
on
t
he
DD
501
an
d
t
h
e
TRIG'D/GATED
lig
h
t
on
t
he
P
G
508
will
b
e
off
until
t
h
e
DD
501
is
t r
igge
r
ed
.
Up
o
n
receipt
of
α
trigger,
all
lig
h
ts
will
ill
u
mi
nate
.
If
n
ot,
check
t
he
set
up
an
d
slig
h
tly
a
d
j
ust
t
he L
E
VEL
co
n
trols
as
necessary
.
RE
V
.
Α
,
A
PR
.
1977
25
n
s
,
.
._
_
.__
..
ο
PG
508
+
T
R
IG
O
U
T
At
PG
508
r
ep
etitio
n
rates
b
elow
abou
t
20
MHz
t
he
ext
r
a
pu
lse
cou
n
t
is
o
ne
.
Fr
o
m
ab
out
20
MHz
to
50
MHz
t
he
w
orst
case
ext
r
a
pu
lse
co
u
nt
is
two
.
T
he
a
bove
conditio
ns a
r
e
t
r
ue
only
wit
h
te
n
i
nch
or
sh
o
r
te
r
interco
nn
ecti
n
g
cables
.
Fig
.
1-7
.
Typ
ical
pr
op
agatio
n d
elays
u
sing
PG
508
wit
h
DD
501
i
n
cou
n
ted
bu
r
st
m
ode
at
50
MHz
re
p
etitio
n
rate
.
_
χ
STA
R
T
TRIGG
ER
TODD
501
(5
n
s
o
r
lo
nge
r )
DD
501
DE
L
AY
I
N
TER
V
A
LO
U
TP
U
T
25
n
s
35
n
s_
.
.
Ι
TOTAL
TIME
FROM
DD
501
STA
R
T
TRIGGER
TO
F
I
R
ST
PG
508
PUL
SE
IS
-
85 ns
.
Operating
I
n
st
r
uctio
n
s-
P
G
508
Set
t
h
e
EV
EN
TS
D
EL
AY
CO
U
NT
Οη
t
he
DD
501
fo
r
o
n
e
less
t
h
a
n
t
he d
esired
num
b
er of
cou
n
ts
up
to
P
G
508
re
p
etitio
n
r
ates
of
ab
out 20
MH
z
.
See
below
fo
r
f
u
rt
he
r
i
n
for
m
atio
n
.
If
n
ecessary,
α
single
t r
igger
maybe
o
b
tai
ned
by
r
otati
n
g
t
h
e
DD
501
START
LEV
EL
co
n
t
r
ol
t
hr
oug
h
t
he
0
p
ositio
n
,
wit
h
no
extern
al
trigger
applie
d
.
Α
si
n
gle
t
r
igge
r
may
also
be
obtai
n
edby
u
si
n
g
t
he
TEKTRONIX
ma
n
ual
(O
n
eS
h
ot)
Trigge
r
Generator,
Te
k t r
onix
P
art
Nu
m
be
r
016-0597-00
.
All
ot
h
e
r
DD
501
a
nd
P
G
508
o
pe
r
ati
ng
co
n
trols
fu
n
ctio
n normally
.
Due
to
p
ropagation d
elays
in
t
h
eP
G
508,
DD
501 an
d
t
he
i
n
terco
nn
ecti
ng
cables,
one
or
more
pulses
in
a
dd
itio
n
to
t
h
e
desi
r
e
d
n
u
m
be
r
are generated
w
hen
t
h
eP
G
508
re
p
etitio
n
r
ates
a
r
e
set
between
20
MHz
and
50
MHz
.
T
h
ese
ext
r
a
p
u
lses
are
consistant
for
any
given
fre
q
uency
i
rr
esp
ective of
the
d
esire
d
EVEN
TS
DE
L
AY
CO
U
NT
setti
ng
.
To
determine
t
h
e
n
u
m
ber
of
extra
pu
lses
for
α
give
n
PG
508
perio
d
,
set
t
h
eP
G
508
an
d
t
he
DD
501
controls
as
previously
described
.
Now
a
dju
st
t
he
P
G
508
TRIG/GATE
L
EVEL
o
r t
h
e
DD
501
EV
ENTS
L
E
V
E
L
fo
r t
h
e
same
n
umbe
r
of
extra
p
ulses
at
DD
501
E
VE
N
TSDE
L
AY
CO
U
N
T
setting
of
ze
r
o a
nd
n
ine
.
EXTRA
TRIGGER
OU
TP
UT
WH
E
N
O
PER
ATI
NG
PG
508
at
50
MHz
Ι
.
<-----
D
E
SI
R
ED
CO
U
NT
O
F F
I
VE
EXTRA
P
G
508
P
U
L
S
E
O
U
T
PU
Τ
PUL
S
ES
αοαα
-
α
i

Table of Contents

Other manuals for Tektronix PG 508

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix PG 508 and is the answer not in the manual?

Tektronix PG 508 Specifications

General IconGeneral
BrandTektronix
ModelPG 508
CategoryPulse Generator
LanguageEnglish

Related product manuals