EasyManuals Logo

Tektronix PG 508 User Manual

Tektronix PG 508
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
I
n
ter
n
al
A
dju
stme
n
t
Pr
oce
dure---PG
508
M
aintenance
Services
Available
Circuit
B
oar
d
R
e
m
oval
'Tektronix,
I
n
c
.
p
rovi
des
com
p
lete
instrument
repair
an
d
a
dju
stme
n
t
at
local
F
ield
Service
Ce
n
ters
a
nd
at
t
he
F
actory
Service
Center
.
Co
n
tact
your
local
Te
k
tro
n
ix
F
ield
Office
or
R
eprese
n
tative
for
furt
he
r
i
n
fo
r
matio
n
.
R
efer to
t
he
TM
500-series
p
ower
mo
du
le
man
u
als
for
complete
maintenance
i
n
formation
.
F
or
re
p
laceme
n
t
of
ca
m
switch
contacts,
cam
switc
h
re
p
air
k
its
are
available
from
Te
k
tro
n
ix
.
To
obtai
n
t
h
e
k
its,
contact
yo
ur
local
Te
k
tronix
F
iel
d
Office
o
r
r
e
pr
ese
n
tative
.
If
tro
u
ble
exists
in
t
he
o
u
tp
u
t
am
p
lifier,
remove
t
h
e
+
and
---
trac
k
i
ng
power
su
pp
ly
ju
m
pe
r
s
located
as
sh
ow
n
i
n
t
he ad
j
ustme
n
t
locatio
n
ill
u
stratio
n
.
T
h
is
completely
isolates
t
he
trac
k
ing
p
ower
su
pp
lies
from
t
he
o
u
t
pu
t
ci
r
cuit
r
y
.
To
r
e
m
ove
t
h
eo
u
t
p
ut
circuit
boar
d an
d
gain
access
to
t
h
e
compo
n
ents
on
t
h
e
varia
b
le
tra
n
sitio
n
timing
board,
first
remove
t
h
e
four
screws
on
t
h
e
p
lug-in
r
ear
p
a
n
el
a
n
d
remove
t
h
e p
a
n
el
.
Next
remove
t
he
TRA
N
SITIO
N
TIME
kn
ob
.
Disconnect
t
he
coaxial
cable p
lugs
a
nd
u
nplug
all
t
h
e wires
co
nn
ected
to
t
h
e
output
or
tra
n
sitio
n
time
boar
ds
.
Fi
n
ally,
remove
t
h
efourscrewsholding
t
h
eoutput
boar
d
to
t
he
plug-in
fra
m
e
an
d
remove
t
he
two
boards
by
sli
d
ing
toward
t
h
e
r
ear
of
t
h
e
p
lug-i
n un
til
t
he
TRAN-
SITION
TIME
sh
aft
clears
t
he
front
p
a
n
el
h
ole
.
Now
lift
t
he
b
oards
an
d
remove
t
h
em
f
r
om
t
he
mainframe
.
To
remove
t
h
e
inp
u
t
b
oard
remove
t
h
e
wi
r
es
an
d
cables
to
t
h
e
i
np
ut
boar
d
an
d
t
he
two
screws
h
ol
d
ing
t
he
b
oar
d
to
t
h
e
ch
assis
.
To
remove
t
he
timi
ng b
oar
d
,
first
remove
t
he
rea
r
pa
n
el,
as
exp
lai
ned
above
.
T
hen
remove
t
h
e
PE
RIOD,
DE
L
AY,
and
D
UR
ATIO
N
k
nobs
from
t
h
eir
sh
afts
.
Disconnect
all
wires
an
d
cables
leading
to
t
h
e
timi
ng
boar
d
.
R
emove
t
h
e
four
screws
h
olding
t
he
timi
n
g
board
to
t
h
e
spacers
.
Sli
de
t
h
e
timing
boar
d
toward
t
he
rearof
t
he
pl
u
g-in
until
t h
es
h
afts
clear
t
he
fro
n
t
p
an
el
an
d
lift
t
h
e boar
d
out
.
Test
E
qu
ipme
n
t
F
or
complete
calibratio
n
of
t
h
eP
G
508,
t
h
e
followi
ng
equip
me
n
t
is
recommen
ded
:
P
ower
mo
du
le
wit
h
fou
r
compartme
n
ts
or
more,
TEKTRONIX
TM
504
.
Digital
voltmeter
wit
h
r
an
ges
greater
t
han
±26
V,
TEKTRONIX
D
M
502
or
equivalent
(re
q
uires
α
TM
500-
series
power
module)
.
Digital
cou
n
ter
capa
b
le
of
fre
quen
cies
to 51
MHz,
TEKTRONIX
DC
504
(requires
α
Μ
500-series
p
ower
m
o
du
le)
.
5
k
Hz
to
500
kH
z
sq u
are-wave
ge
n
erato
r
wit
h
variable
fre
quency
co
n
trol
and
external
triggering
cap
abilities,
TEKTRONIX
P
G
501
(req
u
ires
α
TM
500-series
power
mo
d
ule)
.
Complete
oscillosco
pe system,
sampling
and
real
time,
capable
of
fait
h
ful
re
p
ro
d
uctio
n
to
at
least
500
MHz
.
TEKTRONIX
5440
mainframe,
5
Α
45
real
time
vertical
amplifier,
5
Β
42
real
time
d
elayi
ng
sweep
pl
u
g-i
n
,
a
nd
5S14
N
sa
m
pler
p
lug-i
n su
ggeste
d
.
General
Two
flexible
p
l
u
g-i
n extend
er
cables,
Te
k
tronix
Part
No
.
067-0645-02
.
50
Ω
42
inc
h
coaxial
cab
le
wit
h
bnc
co
nnecto
r
s,
Te
k
tronix
P
art
No
.
012-0057-01,
or
equ
ivale
n
t
.
50
Ω
te
r
mination
,
bnc connectors,
Tektronix
P
art
No
.
011-0049-01,
o
r
e
q
uivale
n
t
.
50
Ω
10
Χ
atte
nuato
r
,
b
nc
conn
ectors,
Te
k
tronix Part
No
.
011-0059-02,
or e
qu
ivale
n
t
.
Bn
c female
to
d
ual
banana ad
apter,
Te
k
tronix
P
art
No
.
103-0090-00
.
F
or
easy
access
to
all
ad
ju
stments,
calibrate
t
h
e
P
G
508
u
si
ng
t
h
e
extender
cables
.
M
ake
certai
n
t
h
e
cables
a
n
d
pl
u
g-in
are p
ro
p
erly
co
nn
ecte
d
;
top
of
eac
h end
of
exten
der
cable
to to
p
of
p
ower
mo
d
ule
and
to
top
of
pl
ug-
in
.
A
dj
ustments
a
r
e
locate
d
on
t
h
e outp
u
t
b
oar
d
(rig
h
t
si
de
of
i
n
strume
n
t),
period
board
(left
si
d
e
a
nd
to
p
)
a
nd
tra
n
sitio
n
boar
d
(t
hroug
h
t
he b
ottom
of
t
he
i
n
strument)
.
M
a
k
e
ad
j
ust
m
en
ts at
an a
m
b
ie
n
t
temperat
u
re
between
i-20°C
and
+30°C
.
R
ecomme
nd
ed
recali
b
ration
interval
is
2000
h
ours
of
o
p
eration
or
six
mont
hs,
w
h
ic
hever
occurs
first
.
O
u
tput
V
oltage
Co
n
trol
K
no
b
C
h
ec
k
or
A
d
j
ust
m
e
n
t
To
check
or
reset
t
he
OU
TP
U
T
(
VO
L
TS)
co
n
trol
k
nobs,
u
se
t
h
e
followi
ng p
rocedure
.
Connect
an
oscillosco
pe
to
t
h
e P
G
508
O
U
TP
U
T
co nnecto
r
.
Set
t
h
e
D
UR
ATIO
N
control
to
t
h
e
SQ
W
A
VE
position,
an
d
t
he
PER
IOD
control
at
t
h
e
2
ms
p
ositio
n
.
Set
t h
e HIG
H
L
E
V
E
L k
nob
for
an
o
u
t
p
ut
level
of
a
b
o
u
t
+5
V
on
t
he
oscillosco
p
e,
an
d
t
he
L
O
W
L
EVE
L for
0
V
.
If
t
he
L
O
W
L
E
VEL
kn
o
b
does
not
point
to 0,
loosen
t
he
set
screw
an
d
reset
t
he
kn
ob
to
theO
mar
k
on
t
he
front
panel
.
Now
set
t
h
eL
O
W
L
EVE
L
k
nob
for
α
readi
ng
of
about
-5
V,
an
d
t
he
H
IG
H
LE
V
EL
for
0V
on
t
he
oscilloscope
.
If
t
he
H
IG
H
LE
V
EL kn
ob
d
oes
n
ot
point
to 0,
loosen
t
h
e
setscrew
and
rea
dj
ust
.
1
.
A
d
j
ust 5
.2
V
Supp
ly
Connect
t
he
-
Ι -
lea
d
from
t
he
D
VM
to
t
h
e
p
oi
n
t
labeled
- Ι
-5
.2
V
in
t
h
e
ill
u
stratio
n
and
t
h
e--
lead
to
grou
nd
.
A
dj
ust
R
1210,
5
.2,
for
α
readi
n
g
of
.
ί
-5
.2
V
.
2
.
Ad
j
ust
2
μ
s Perio
d
Con
nect
t
he
coaxial
ca b
le
to
t
he
+TRIG
OUT
co
n
nec-
tor
.
Co
nn
ect
t
he
50
Ω
ter
m
inatio
n
to
t
he
ot
h
e
r
end
of
t
he
cable
an
d co
nn
ect
t
he
termi
n
atio
n
to
t
he
co
u
nter
i
n
pu
t
.
Set
t
he
cou
n
ter
to
rea
d
500
kH
z
.
Set
t
he
PER
IOD
con
trol
to
t
he 2
μ
s
position
.
M
ak
e
certain
t
he
CA
L
k
no b
is
f
u
lly
ccw
.
Ad
j
ust
R
186,
P
er,
for
α
freque
ncy
of
500
kH
z
.
3
.
A
d
j
ust
Sym
m
et
r
y
M
ai
n
tai
n
t
he
PER
IOD
as
i
n
t
he
p
revious
step
and
t
he
CA
L k
nob
f
u
lly
cloc
k
wise
.
Co
nnect
t
he
+TRIG
O
U
T
t
h
ro
u
g
h
t
he
coaxial
cable a
nd
termination
to
t
h
e
vertical
am
p
lifier
i
nput
of
t
he
oscilloscope
.
Set
t
h
e
oscillosco
pe
swee
p
rate
so
t
h
at
o
n
e-
h
alf
cycle
of
t
h
e
wavefor
m
is
d
isplaye
d over
most
of
t
h
e
graticule
.
Wh
ileswitc
h
ing
from
i-
slo
p
e
to
--
slo
p
e
on
t
h
e
oscillosco
pe
triggeri
n
g,
a
dj
ust
R
180,
Sym,
so
t
h
at
t
he
waveform
transitions
occur
at
exactly
t
he
same
point
on
t
h
e
oscillosco
p
e
graticule
.
R
EV
.
CA
PR
197
8

Table of Contents

Other manuals for Tektronix PG 508

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix PG 508 and is the answer not in the manual?

Tektronix PG 508 Specifications

General IconGeneral
BrandTektronix
ModelPG 508
CategoryPulse Generator
LanguageEnglish

Related product manuals