EasyManuals Logo

Tektronix PG 508 User Manual

Tektronix PG 508
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
14
.
A
d
j
ust
N
ormal
Complement
B
alance
C
h
ange
t
he
osci
Ι
loscope
swee
psp
eed
to
0
.5
μ
s
.
Set
t
he
O
U
TP
U
T
(
V
O
L
TS)
H
IG
H
and L
O
W
level
controls
totheir
0
positio
n and
set
t
he N
O
RM
/CO
MPL
E
ME
NT
button
out
.
S
h
ort
t
he
center
termi
n
als
of
t
h
e
NORM/COMPLEMENT
switc
h as s
h
ow
n
in
t
h
e
illustration
.
Increase
t
he
vertical
gai
n
of
t
he
oscillosco
p
e
by
α
factor
of
10
.
Νοω
ad
j
ust
R
910,
Ν
/C
ΒαΙ
,
for
eq
ual
h
ig
h
and
low
level
output
voltages
(no
signal)
.
R
emove
t
he sh
ort
from
t
he
switc
h
terminals
.
15
.
A
dj
ust
Gai
n
U
si
ng
t
he voltmeter
co
n
nected
to
t
he
bottom
center
termi
n
al
of
the
Ν
0
R
Μ
/CO
MPLEMEN
T
switc
h
and
grou n
d,
a
dj
ust
t
he
O
U
T
PU
T"
(
V
O
L
T'S)
L
O
W
LEV
E
L
control
for
1
.33
V
dc
.
Now
co nn
ect
t
h
e
voltmeter
to
t
h
e top
center
pin
of
t
he
N
O
RM
/CO
MPLEM
E
N
T
switc
h a
n
d
,
wit
h
out
movi
n
g
t
he L
O
W
L
EV
EL
co
n
trol,
set
t
he
O
U
T
PU
T
(volts)
HIG
H
LEV
E
L
control
for
3
.87
V
dc
.
A
dj
ust
R
885,
Gain,
fo
r
a
pea
k
to
p
eak outp
ut
am
p
litu
d
e
of
10
V
into
50
Ω
.
16
.
Ad
j
ust
H
ig
hL
evel
Trac
k
ing
Wh
ile
o
b
serving
t
he
wavefor
m
low
level
on
t
he os-
cillosco
p
e,
vary
t
he
H
IG
H
LEV
EL
from
0
V
am
p
litude
to
maximum
amplitu
d
e
(10
V)
and ad
j
ust
R
915,
H
i
Trk
,
for
min
imum
sh
ift
.
17
.
Ad
j
ust
L
ow
L
evel
T
rac
k
ing
Observe
t
h
e
waveform
h
ig
h
level
on
t h
e
oscilloscope
and
vary
t
h
e
L
O
W
L
E
V
E
L
control
from
0
V
to
m
aximum
am
p
litude
.
Ad
j
ust
R
920,
L
o Tr
k
,
for
minimum
s h
ift
.
18
.
Ad
j
ust
Offset
Connect
t
h
e
voltmeter
to
t
h
e
bottom
center
pi
n
of
t
he
N
O
RM
/CO
MPL
E
MEN
T
switc
h
.
Connect
t
he
negative
lead
to
grou
n
d
.
Set
t
h
e
L
O
W
LE
V
EL
co
n
trol
for
α voltmeter
readi
ng
of
2
.600
.
Now
a
d
j
ust
R
925,
Offset,
u
n
til
t
he
waveform
low
level
is
at
0
V
on
t
he
oscillosco
pe
.
19
.
Ad
j
ust
Output
Impe
d
ance
Set
t
h
e
P
erio
d
at
ΕΧΤ
TRIG
O
R
MAN
and
t
he
D
UR
ATIO
N
at
ΕΧΤ
DU
R
.
M
ake
ce
r
tai
n
t
h
e
"
B
RIG/GATE
LE
V
E
L
con
trol
is
t
u
rned
cloc
k
wise
enoug
h
so
t
he
Τ
'RIG'D/GATED
lig
h
t
is
lit
.
Co
nnect
t
he
O
U
T
PU
T
of
t
he
P
G
508
to
t
h
e
digital
voltmeter
through
a
coaxial
cable
and
b
nc
female
to
d
ual
b
anana
adapter
.
Ad
ju st
t
he HIG
H
LEV
E
L
for
α
rea
d
ing
of
10
.0
V
on
t
h
e
voltmete
r
.
Connect
a
50
Ω
termi
n
atio
n
between
t
he
coaxial
cable
and
ad
apter
.
A
dj
ust
R
1020
for
α
rea
d
ing
of
5
.0
V
on
t
he voltmeter
.
20
.
Ad
j
ust
Out
p
ut
Amplifier
Connect
t
he
OUTPUT
terminal
of
t
h
eP
G
508
t
hrough α
coaxial
cable
a
n
d
10
Χ
atte
nuator
to
t
he
input
of
t
he
sam
p
li
ng
oscillosco
pe
.
Set
t
h
e
sam
p
li
n
g
oscillosco
pe
swee
p sp
eed
at
20
ns
p
er
d
ivision
.
Set
t
he
DURATION
at
.1
μ
s,
PERIOD
at
.2
μ
sa
nd
t
he
TRANSITION
TIME
at5
ns
.
Obtain α
free
r
unn
ing
u
n
d
elayed output
waveform
.
Ad
j
ust
t
he
O
U
TP
U
T
(
V
O
L
TS)
H
IG
H
LE
V
EL an
d
L
O
W
L
E
VEL
co
n
trols
for
α 10
V
pea
k
to
p
eak
out
p
ut
waveform
centered
arou nd 0
V
.
Ad
ju st
R
1050,
C1024a
nd
R
1024fort
h
efastest
risetime
an
d
least
aberratio
n
s
on
t
h
e
traili
n
g
tra
n
sitio
na
nd
cor
n
er of
t
he p
ulse
.
Internal
A
d
j
ustme
n
t
Procedure--PG
508
21
.
A
d
j
ust
Control
Error
L
ig
h
t
Co
nnect
t
h
e
OU
T
PU
T
termi
n
al
of
t
h
eP
G
508
t
hrough α
coaxial
cable
and
50 oh
m
termi
n
atio
n
to
t h
e
input
of
t
h
e
real
time
oscilloscope
.
Set
t
he
oscillosco
pe
for
α
vertical
se
n
sitivity
of
1
V
wit
h
do
coupling
and
for
α 10
n
s
swee
p
r
ate
.
Set
D
UR
ATIO
N
at
10
n
s,
PER
IOD
at
20
ns,
TRA
N
-
SI
1'
ΙΟΝ
TIME
at
5
ns,
TR
AI
L
I
N
G
a
nd LE
ADI
N
G
co
n
trols
fully
ccw,
M
OD
E
UN
D
L
Y
b
u
tto
n
i
n
and
M
OD
ED
EL
AY
bu
tto
n
out
.
Set
all
TR
IGG
ER
I
N
G
buttons
to
ou
t
p
osition,
N
O
RM
/CO
MPLEMEN
T b
u
tto
n
out
and
PRE
SET/
V
A
R
button ou
t
.
A
dj
ust
t
he
O
U
TP
U
T
(
V
O
L
TS)
HIG
H
LEV
E
L
a
nd
L
O
W
LE
V
EL
co
n
trols
for
α
d
is
p
lay
of
4
,
2
.5
d
ivisions
an
d
--2
.5
divisions
ce
n
tered
aro
u
nd
0
V
.
A
dj
ust
LE
ADI
N
G
co
n
trol
cw
to
w
here
t
he top
of
t
he
waveform
is
d
ecreased
i
n
am
p
litude
by
10
ο
/
ο
(0
.5
d
ivision)
.
A
dju
st
C749
for
α
flas
h
i
n
g
indication of
t
he
CO
N
TRO
L
ERR
O
R
lig
h
t
.
NO
ΤΕ
If
t
h
e
CO
N
T
R
O
L
ERR
O
R
lig
h
t
does
not
f
las
h
,
a
d
just
LE
ADI
NG
cont
r
ol
cw
to
w
he
r
e the
to
p
of
waveform
is
d
ecrease
d
by
5
ο/ο
more
(0
.25
division)
;
t
h
enad
j
ust
C749
again
fo
r
α
flashing
in
d
icatio
n
.
If
t
he
lig
h
t
still
cannot
be
ma
d
e
to
flas
h
with
a
d
justment
of
C749,
conti
n
ue
adjusting
t
h
e
LE
ADI
N
G
control
cw
in
intervals
of
α
5
ο/ο
decr
ease
until
a
d
justme
n
t
of
C749
results
in
α
flas
h
i
n
g
indication
of
t
h
e
CO
N
T
RO
L
ERR
O
R
lig
h
t
(do not
excee
d
α
50%
ο
dec
r
ease
in
waveform
am
p
litude)
.
R
ea
dj
ust
C749
to
α
point
w
h
ere
t
h
e
CO
N
T
R
O
L
ERR
O
R
lig
h
t
is
j
ust
exti
n
guis
h
ed
.
R
etur
n
LE
ADI
NG
control
to
its
fully
ccw
p
ositio
n
.
A
dju
st
TRAI
L
I
N
G
con
trol
cw
to
w
h
ere
t
h
e
bottom
of
t
h
e
displayed
waveform
is
decrease
d
i
n
amplit
ud e by 10
ο
/ο
(0
.5
d
ivisio
n
)
.
Ad
j
ustC744foraflashing
i
n
dicatio
n
of
t
he
CO
N
TRO
L
ERR
O
R
lig
h
t
.
NO
ΤΕ
If
t
h
e
CO
N
T
RO
L
ERR
OR
lig
h
t
d
oesnot
flas
h
,
a
d
just
T
R
AIL
I
NG
control
cw
to
w
he
r
e
t
h
e
bottom
o
f
waveform
is
d
ecrease
d
by
5
ο/ο
more
(0
.25
division)
;
t
h
en a
d
just
C744
again
for
a
flashing
indication
.
If
t
h
e
lig
h
t
still
cannot
be
made
to
flas
h
with
a
d
just-
ment
of
C744, continue
adjusting
t
he
T
R
AI
L
I
N
G
cont
r
ol
cw
in
i
n
tervals
of
α 5
ο/ο
d
ecrease
un
til
a
d
justment
of
C744
results
in
α
flas
h
i
n
g
i
nd
ication
of
t
h
e
CO
N
T
R
O
L
ERR
O
R
lig
h
t
(
d
o
not
excee
d
α 50
ο/ο
decrease
in
waveform
am
p
litude)
.
R
ea
dj
ust
C744
to
α
point
w
h
ere
t
h
e
CO
N
TR
O
L
ERR
O
R
lig
h
t
is
j
ust
extinguis
h
ed
.
R
eturn
TRAI
L
I
NG
control
to
its
fully
ccw
p
ositio
n
.
Go
back
to
ste
ps
3,
7,
and 8
a
n
d
p
erform
t
he a
d-
j
ustments
in
t
h
ese
steps,
if
necessary,
for
optimum
performa
nce
.
REV
.
Β
A
PR
1978

Table of Contents

Other manuals for Tektronix PG 508

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix PG 508 and is the answer not in the manual?

Tektronix PG 508 Specifications

General IconGeneral
BrandTektronix
ModelPG 508
CategoryPulse Generator
LanguageEnglish

Related product manuals