Command Descriptions
2–142
TDS Family Oscilloscope Programmer Manual
:
MAXRate
:
CLOck
HORizontal
?
<Space> <NR3>
<NR3> is rounded up to the nearest allowable external clock rate.
HORIZONTAL:CLOCK:MAXRATE 50
sets the maximum external clock rate to 50 clocks per second.
HORizontal:DELay? (Query Only)
Returns all horizontal delayed time base parameters. The commands HORizon-
tal:DELay:SECdiv and HORizontal:DELay:SCAle are identical so only
HORizontal:DELay:SCAle will be returned.
Horizontal
HORizontal?, HORizontal:DELay:MODe?, HORizontal:DELay:SCAle?,
HORizontal:DELay:SECdiv?, HORizontal:DELay:TIMe?
HORizontal:DELay?
:
DELay
?
HORizontal
HORIZONTAL:DELAY?
might return the delay parameters :HORIZONTAL:DELAY:MODE RUNSAFĆ
TER;SCALE 1.0E-6;TIME: 16.0E-9
HORizontal:DELay:MODe
Selects the mode for the delayed time base. This is equivalent to setting Time
Base in the Horizontal menu.
Horizontal
HORizontal:DELay:TIMe
HORizontal:DELay:MODe { RUNSAfter | TRIGAfter }
Arguments
Examples
Group
Related Commands
Syntax
Examples
Group
Related Commands
Syntax