Command Descriptions
2–264
TDS Family Oscilloscope Programmer Manual
TRIGger:MAIn:PULse:WIDth:POLarity { NEGAtive | POSITIVe }
TRIGger:MAIn:PULse:WIDth:POLarity?
TRIGger :
:
PULse
MAIn
WIDth :
POLarity
<Space>
?
:
POSITIVe
NEGAtive
NEGAtive specifies a negative pulse.
POSITIVe specifies a positive pulse.
TRIGger:MAIn:PULse:WIDth:WHEn
TDS 5XXA, 6XXA, & 7XXA Only
Selects the condition when the trigger occurs. This is equivalent to selecting the
condition in the Pulse Width Trig When side menu.
Trigger
TRIGger:MAIn:PULse:WIDth:WHEn { OUTside | WIThin }
TRIGger:MAIn:PULse:WIDth:WHEn?
<Space>
?
TRIGger :
:
OUTside
WIThin
PULse
MAIn
WIDth :
WHEn
:
OUTside specifies a trigger when the duration of the pulse is greater than the
high limit or less than the low limit specified. The high and low limits are
specified with the TRIGger:MAIn:PULse:WIDth:HIGHLimit and
TRIGger:MAIn:PULse:WIDth:LOWLimit commands respectively.
WIThin specifies a trigger when the duration of the pulse is within the high and
low limits. The high and low limits are specified with the
Syntax
Arguments
Group
Syntax
Arguments