GB
TAB. 2
FUNCTION
n. Dip
OFF ON DESCRIPTION NOTE
Step-by-step input
and
radio channel mode
1
Open - Stop - Close
During opening, upon pressing the P/Pbutton the gate stops, pressing it again the gate closes.
During closing, upon pressing the P/Pbutton the gate stops, pressing it again the gate opens.
2
1
Open - Close
During opening, upon pressing the P/Pbutton the gate stops for a few seconds and then closes.
During closing, upon pressing the P/Pbutton the gate stops for a few seconds and then opens.
2
1
Open
During opening, pressing the P/Pbutton has no effect. During the pause, pressing the P/Pbutton has no effect.
During closing, upon pressing the P/Pbutton the gate stops for a few seconds and then opens.
2
Condominium function
1
Open - Close
During opening, pressing the P/Pbutton has no effect. During the pause, upon pressing the P/Pbutton the gate closes.
During closing, upon pressing the P/Pbutton the gate stops for a few seconds and then opens.
2
Cut out of opening control
Jolly
input mode
3
Safety edge
Safety edge activation reverses the direction for a few seconds. After safety edge activation the control unit locks; re-closing is
cancelled. Use a N.C. contact
4
3
Clock
Upon closing the input that is short-circuited towards the common terminal, the gate opens and remains open until the contact is
broken. Use a N.O. contact
4
3
Photocell
During both opening and closing, activation of this photocell stops the gate until it is reset. The next movement is always in the
opening direction. Use a N.C. contact
4
3
Pedestrian access
The gate open spartially for a programmable time (see“pedestrianopeningprogramming”). Use a N.O.contact.
4
Pre-flashing light 5
Cut out
The flashing light is powered at the same time as the motor.
Connected
The flashing light is powered 5 seconds before any movement.
Re-closure 6
Cut out
After one complete opening, the control unit only closes again with a manual control.
Connected
After one complete opening, the control unit closes automatically after the programmed pause time.
Photo test 7
Cut out
Function bypassed
Connected
See text at page 42.
Brake 8
Cut out
Unless strictly necessary, it is advisable to cut out the brake.
Connected
The m. brake serves to overcome the inertia of heavy aut. systems. When the brake is enabled it activates at the end of every m
Slowdown 9
Cut out
There is no slowdown in the last part of travel.
Connected
With the slowdown function connected, the motor halves its speed towards the end of every gate movement.
Reclosing after the
photoelectric cells
10
Cut out
Function bypassed
Connected
The activation of photoelectric cell reduces the pause time for whatever is value previously was to 2 seconds.
Note: the standard initial configuration is shown in part 11 of fig. 1