DateCode Number: Series Model number Draft
TVLink RS868
T246.04 23-02-2011
TVPRP868A01

TELECOAUTOMATIONSRL-VialedelLavoro,5-31014ColleUmberto(TV)ITALY
TELEPHONE:++39.0438.388511FAX:++39.0438.388536
EN
DIGITAL RADIO CONTROL SYSTEM PRP
GENERAL DESCRIPTION
Electronicfortheremotecontroloftubularmotorsforrollerblindswithlimit
switchinsideoroutsidethemotor,radioreceiversectionwithtransmitterchannel
memorisationbymeansofpushbuttonorviaradio.
Possibilitytoconnecttwoasafetydevicelikephotocells,safetyedgesorsimilars
withaauto-testcontrolbeforeeveryclosingmovement.
Possibilitytoconnectsafetydeviceswitha24V of80mAmaximumload
(CSP+FTC).
Possibilitytoconnecta230V ashinglamp,whichworksduringtheworking
time.Possibilitytoconnecta230V courtesylightwith3min.workingtime.
Plasticbox(outsideuse)equippedwithPG11clamps.
Possibilityofcentralisedcontrolsforsimultaneouscontrolofseveralappliances.
Workingtimeandautomaticclosingtimeadjustablefrom3sto1.5minutesby
meansofaninternaltrimmer.
Attention:workingtimeisreadatthebeginningofanymovement,thereforea
settingwhichhasbeendoneduringthemovement,willbenotconsidered.
Possibilitytoconnectanexternalswitchwithopen,stop,closefunction.
Installation
The subject appliance must be installed only by qualied technical personnel in
compliance with the standards on the subject of automatic openings, curtains,
blinds, rolling shutters. All connections must be rated for a single-phase power
supply of 230V. For the disconnection from the power line, use an all-pole switch
with contact with an opening of at least 3,5mm. Only suitable materials for the
connections must be used to guarantee insulation that complies with current
standards on the subject of electrical safety. The programmer carries out move-
ment commands; all the necessary safety devices are to be seen to separately.
Keepseparatethe230Vwiresfromthesafetywireswithlowtension.Theearth-wires
mustbexedbymeansofanadditionalfastening;thisfasteninghastobedoneby
qualiedtechnicalpersonnelduringtheinstallationphase.
TheappliancehasbeentestedwithapowersupplywiretypeH05VV-F;thepower
supplywiresforoutdoorusehavenottobelighterthantheordinarywirestype
H05RN-F.ThesafetydeviceshavetobeinconformitywithEN12978.
Theinstallationofthecontrolunithastobedonebyxingtheboxverticallywiththe
clampsdownwards.
TheprogrammerisinconformitywiththeRAEEandRoHSdirective.
Dip- switch functions
Dip1: Insertion automatic closing
Attention:Iftheclosingmovementisin“presentman”mode,letthedipinOFF-
position.
Dip1ON: automaticre-closingisactivated
Dip1OFF: automaticre-closingisdeactivated
Times learning
Working time ( to be set always)
-Theworkingtimeshouldbelearntbyplacingthecontrolunitinsemi-automatic
mode(Dip1inOFF-position),thensetthetimeatavaluethatis3shigherthanthe
timeofthewholeopeningorclosingstroke.
-Attention!Whenthecontrolunitoperatesinsemi-automaticmode,theworking
timeisreadateachmovementstartandthetrimmeroperatesassettingofthe
workingtime;variationsofthetrimmerduringthemovementarenotconsidered.
Time of automatic re-closure (only with activated automatic re-closing)
Placethedip-switchn°1inONposition.
-Thedisplacementofthedip-switchfromOFFtoONmemorizestheworkingtime
thatwassetbeforeinthesemi-automaticmode(thememorizedworkingtimecould
bemodiedonlybyreturninginthesemi-automaticmode).
-Thetrimmeroperatesonlyassettingofthepausetime(automaticre-closure).
-Warning!Whenthecontrolunitoperatesinautomaticmode,thepausetimeisread
ateachmovementstart;variationsofthetrimmerduringthepausearenotconsidered.
1
Dip4: TA-TD function
Dip4-ON: TAturnintoTD;dynamicpush-button
Dip4-OFF: TAopeningpush-button
Dip5: Test deactivated- input pneumatic buffer barrier CSP
Dip5-ON: Testdeactivated
Dip5-OFF: Testactivated
Dip6: Memorisation of buffer barrier type
Dip6ON:Normalfunctioning
Dip6OFF:Memorisationphase
Attention!
Duringthememorisationofthebufferbarriertype,thecontrolunithastobe
connectedtothebufferbarrier.Procedure:
-SetthejumperJ1ontheusedbufferbarriertype.
-SwitchDip6onOFF,thebuzzerwillsoundcontinuously.
-Whenthecontrolunithasrecognisedthebufferbarriertype,theCSPledwillturn
on.
-SwitchDip6onON.
Ifthewillnotturnonorash,controltheconnectionsorthesettingofthebuffer
barriertypeonJ1.
Safety test function (output terminal boards 22-23)
Thecontrolunitispredisposedtoverifyateveryclosingcontrolthecorrectworking
ofthesafetyinputsCSPandFTC.
ThetestontheinputCSPcanbeexcludedbymeansofdip5,whiletheinputFTC
needsalwaystomakethistest.
Therefore,usetheoutputontheterminalboards22-23toexecutethiscontrol,
normallycloserelaycontact(max.1A,35V).
Attention!
IfoneoftheinputsCSPorFTCisopenduringaclosingcommand,thebuzzerwill
make:
3bipsiftheFTCisopen
4bipsiftheCSPisopen
5bipsifthesafetytestwillnotbepassed.
Itispossibletoclosethedooralsowithanotworkingphotocellorwithanegative
photocelltest(forcedclosing),bypressingandholddowntheclosingpushbuttonTC
after5sthecontrolunitclosesatpresentmancondition,thisfunctionisnotactiveon
theCSP.
Safety input function
- CSP: Normallyclosedinput,withautomaticorsemi-automaticmodeinvertsthe
movementduringclosing,atpresentmanconditionitinvertsthemovement
for2s.
- FTC: Normallyclosedinput,withautomaticorsemi-automaticmodeinvertsthe
movementduringclosing,atpresentmanconditionitinvertsthemovement
for2s.
-TB: Normallyclosedinput,stoppushbuttonstopsthemovementineachcondition.
Possibility to memorise the transmitter in two ways:
1 -Controlfromtwochannelsch1withch2andch3withch4,ch1andch3are
controlsofopening,ch2andch4arecontrolofclosing.
2 -Singlechannelswithdynamicfunction,opening,stop,closing,.
Thetransmittercodecanbeinserted(memorised)ordeleteddirectlyinthereceiver
orviaradiofromthetransmitter.Thislastpossibilityallowstoinsertnewtransmitters
intoanexistinginstallation,withoutactingdirectlyonthereceiver.Thismaybe
carriedouteasilybytheenduserwithoutthehelpoftheinstaller,andguaranteeing
Present-manmode(thismodeisinpresent-mancondition,each
manualandradiocommandremainuntilthefunctionisactivated,
whilereleasingthecontrol,theoutputisimmediatelydeactivated)
Theclosingmovementisinpresent-mancondition,duringthe
openingitisautomatic.
Automaticmode,theopeningandclosingmovementisautomatic.
Automaticmodewithclosingafterthephotocellintervention,only
ifpairedwiththeinsertedautomaticclosing,dip1inON-posi-
tion.Afteranopeningthephotocellresetsthetimeofautomatic
re-closing.
Dip 2
Dip 3
Mode
OFF
ON
OFF
OFF
OFF
ON
ON
ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TELECO AUTOMATION TVPRP868A01 and is the answer not in the manual?

TELECO AUTOMATION TVPRP868A01 Specifications

General IconGeneral
BrandTELECO AUTOMATION
ModelTVPRP868A01
CategoryRemote Control
LanguageEnglish