EasyManua.ls Logo

Temp-Cast 2000 - Troubleshooting Common Fireplace Issues

Default Icon
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Temp-Cast Owner's Manual
September 2012
15
SECTION VIII: TROUBLESHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSES
IMMEDIATE REMEDIES
PERMANENT
REMEDIES
Match blows out
when testing draft.
(Down draft)
cold exterior chimney
negative house pressure
"stack" effect
windy conditions
pre-heat the chimney (pg.
10)
turn off all exhaust fans &
other fireplaces
close windows & doors on
upper floors
use "roof-top"
damper to retain
heat in chimney
install replacement
air device
seal air leaks on
upper floors
review Section IV
Lights okay, but
goes out before
kindling fire gets
started. (Or excess
smoke spillage
after lighting.)
kindling or firewood not
dry
chimney damper closed
obstruction in chimney or
in connection
fresh air intake not open
inside/outside temperatures
are almost the same
use dry kindling and cedar
shavings (or twisted
newspaper)
check that chimney damper
is open
check that air is supply
open
check that chimney is clear
review Section IV,
V & VII
Fire lights okay,
but burns poorly,
with excess smoke
and not enough
heat.
damp wood
wood size too large
insufficient air
wet refractory
stone-cold fireplace
check air intake
use smaller pieces of wood
(max. 5" diameter)
use moisture meter
ensure fireplace has
been cured properly
(Section II)
review Section V
Fire lights & burns
strongly, but not
enough heat is
being produced.
wood not fully dried
no chimney damper
air intake not closed after
fire
not enough wood burned
fireplace not centrally
located
poor insulation
area to be heated too large
fireplace incorrectly
installed
burn more wood
ensure wood is dry, 20% or
less
close chimney damper after
fire
close air supply after fire
split wood into smaller
pieces - max. 5" (120mm)
diameter
keep wood pieces approx.
same size so they burn at
approx. same rate
install roof top
damper
review storage &
moisture % of wood
supply (pg. 12)
review Planning
Guide & Installation
Manual re: correct
facade materials &
installation
use additional heat
sources
upgrade insulation
Fire lights & burns
well, but smoke
spills when door(s)
opened.
chimney, base manifold or
or heat exchange channels
partially obstructed
negative pressure
(especially in "air-tight"
construction)
stack effect
chimney size too small
2
(min. 50 sq.” or 320 cm )
open a window near
fireplace before opening
the door(s)
inspect chimney for too
many offsets or
obstructions
close windows on upper
floors
seal air leaks on
upper floors
install replacement
air unit (pg. 10)
ensure chimney is
correct size (review
Installation Manual)
review Section IV &
Section VII

Other manuals for Temp-Cast 2000