EasyManua.ls Logo

Tempest POWER BLOWER - Page 12

Tempest POWER BLOWER
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Blower Data continued…
ELECTRIC MOTORS:
All electric motors are single phase, 60
Hz, rigid base, 56 frame, with ball
bearings and manual reset overload
protection.
ELECTRIC
UNITS
ENGINE HP CFM S/B RPM WIDTH DEPTH HEIGHT LBS
EB-12 ELECTRIC 1 TEFC 7,683 N.A. 3,450 16.00 19.50 21.50 45
EBS-16 ELECTRIC 1/3
TEFC
3,200 N.A. 1,736 18.75 14.25 19.50 47
EBS-16M
(W/MISTER)
ELECTRIC 1/3
TEFC
3,200 N.A. 1,736 18.75 14.25 19.50 47
EB-16 ELECTRIC 1.5
TEFC
11,804 6 3,450 18.50 20.00 20.50 66
EB-18 ELECTRIC 1 TEFC 8,748 6 1,750 22.25 21.00 24.00 71
EB-21 ELECTRIC 1 TEFC 11,698 7 1,731 25.00 21.00 26.00 72
EB-24 ELECTRIC 1 TEFC 12,867 7 1,736 28.25 22.50 30.00 75
EB-36 ELECTRIC 1 TEFC 13,281 8 1,750 41.50 24.50 43.50 94
Electric Blower Power Requirements*
Based upon 115 v blower on a 20 amp circuit.
BLOWER MODEL MOTOR
HP
STARTING
AMPS
STARTING
WATTS
RUNNING
AMPS
RUNNING
WATTS
EB-12 1.0 48 6,000 16 1,900
EB-16 1.5 54.6 6,300 18.2 2,100
EBS-16 1/3 10.9 1,300 6.3 756
EB-18 1.0 48 6,000 16 1,900
EB-21 1.0 48 6,000 16 1,900
EB-24 1.0 48 6,000 16 1,900
EB-36 1.0 47.3 6,000 12.1 1,452
*Starting amps and watts are momentary
Maximum Power Cord Length (in feet)**
MOTOR H.P. 14 GAUGE 12 GAUGE 10 GAUGE 8 GAUGE 6 GAUGE
1/3 215’ 330’ 550’ 850’ 1,350’
1.0 60’ 95’ 150’ 240’ 380’
1.5 45’ 1.75’ 115’ 190’ 300’
**Calculations based upon one blower connected to 20 amp circuit.