Specifications
Operation
Warning!
Indoor use: Keep the room/area airtight for 10
minutes to obtain more accurate results.
If battery level shows , please charge the detector
promptly to avoid eects during use (also chargeable
when turned o).
*For LKC-1000S+ /LKC-1000S+2nd Only
Note: The above data are from Temtop Laboratory.
Model
Dimensions
Battery Capacity
Battery Life
Charging Output
Display
Weight
Operating
Environment
PM2.5
PM10
HCHO
TVOC*
LKC-1000 Series
177*65.5*32mm (6.9*2.6*1.2 in)
3000mAh
15-18h @ Backlight Level 2
DC5V, 1A
TFT color LCD screen
About 219g (0.48lb)
Temperature: 0~50°C
(32~122°F)
Humidity: 0~90%RH
Measuring range: 0-999ug/m
3
Resolution: 0.1ug/m
3
Accuracy: ±10µg/m
3
(0-100µg/m
3
)
±10%(100-500µg/m
3
)
Measuring range: 0-999ug/m
3
Resolution: 0.1ug/m
3
Accuracy: ±15µg/m
3
(0-100µg/m
3
)
±15%(100-500µg/m
3
)
Measuring range: 0-2mg/m
3
Resolution: 0.01mg/m
3
Measuring range: 0-5mg/m
3
Resolution: 0.01mg/m
3
4