EasyManua.ls Logo

Tenmars TM-188 User Manual

Tenmars TM-188
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HEAT STRESS WBGT
METER
TM-188 / TM-188D
TENMARS ELECTRONICS CO., LTD
HB2TM1880002
Users
Manual
Question and Answer IconNeed help?

Do you have a question about the Tenmars TM-188 and is the answer not in the manual?

Tenmars TM-188 Specifications

General IconGeneral
Resolution (µT)0.01 µT
Data HoldYes
Auto Power OffYes
DisplayLCD
Frequency Range50 Hz ~ 60 Hz
Battery9V battery

Summary

Preface

General Description and Features

Overview of the meter's key features and sensor technology.

Capacitance Sensor Technology

Describes the sensor responsible for accurate WBGT measurements.

Max/Min and Data Hold Functionality

Features for recording and retaining maximum/minimum values.

Low Battery Indicator

Indicates when the meter's battery level is low.

LCD Display with Backlight

Details the display screen and its illumination feature.

Single Data Record Feature

Functionality for single data recording and storage capacity.

Viewing Stored Data Records

Procedure for accessing stored measurement data.

Temperature Unit Selection (°C/°F)

Option to change the temperature display unit.

WBGT Alarm Configuration

Configuration for setting WBGT alarm thresholds.

Auto Power Off and Disable Function

Feature for automatic power-off and its disabling.

TM-188D USB PC Interface

Describes the USB interface for data transfer.

TM-188D Data Logging Capacity

Storage capacity for logged data on the TM-188D model.

TM-188D Sampling Interval Settings

Settings for data logging frequency.

Specifications: WBGT Measurement

WBGT: Indoor/Outdoor (No Sunlight)

WBGT specs for indoor and outdoor use without direct sun.

WBGT: Outdoor (With Sunlight)

WBGT specs for outdoor use with direct sun.

Air Temperature (TA) Specifications

Specifications for air temperature measurement.

Black Globe Temperature (TG) Specs

Specifications for black globe temperature measurement.

Relative Humidity (%RH) Specs

Specifications for relative humidity measurement.

Dew Point Temperature (DEW) Specs

Specifications for dew point temperature measurement.

Wet Bulb Temperature (WET) Specs

Specifications for wet bulb temperature measurement.

Instrument Components and Features

Instrument Dimensions and Weight

Physical dimensions and weight of the instrument.

Sampling Rate and Power Supply Details

Measurement rate and power source requirements.

Battery Life and Environmental Conditions

Battery duration and recommended operating/storage conditions.

Data Output and LCD Screen Specs

Details on data output and LCD screen.

Included Standard Accessories

List of items included with the meter.

Important Warnings and Compliance

Meter Placement and Damage Warning

Warning about potential damage from improper placement.

Annual Maintenance for Accuracy

Recommendation for annual factory maintenance for accuracy.

EMC Standards Compliance Statement

Statement regarding EMC testing and standards compliance.

LCD Display Symbol Guide

Primary Measurement Indicators

Indications for WBGT, TA, TG, WET, DEW, and %RH.

Function and Status Symbols

Symbols for HOLD, MAX/MIN, USB, Alarm, Record, Set, and Auto Power Off.

Unit and Mode Indicators

Indicators for temperature units, indoor/outdoor modes, and time/date.

Battery and Notification Indicators

Symbols for low battery and other status notifications.

Power On/Off Procedures

Turning the Meter On and Off

Procedure to power the meter on or off using the button.

Initial Power-On Display Sequence

Action to display all symbols and firmware version upon startup.

Auto Power Off Function

Automatic Power-Off Operation

Meter powers off after 15 minutes of inactivity.

Alarm Function Control

Enabling and Disabling the Alarm

Procedure to turn the alarm function on or off.

Alarm Function Operational Dependencies

Conditions under which the alarm function is disabled.

Disabling Auto Power Off

Controlling Auto Power Off Feature

Method to disable or enable automatic shutdown.

Conditions That Disable Auto Power Off

Conditions that disable the auto power off feature.

LED Backlight Operation

Activating the LCD Backlight

Turning the LCD backlight on and its auto-off timer.

Temperature Unit Settings

Switching Between °C and °F

Changing the displayed temperature unit (°C/°F).

Measurement Mode Selection

Changing Measurement Modes (WBGT, TA, etc.)

Cycling through measurement units (WBGT, TA, etc.).

Switching IN/OUT Display in WBGT Mode

Switching display between IN and OUT in WBGT mode.

Restrictions on Mode Functionality

Conditions that make the mode function unavailable.

Data Hold Function

Enabling the Data Hold Feature

Activating the data hold feature.

Restrictions on Data Hold Functionality

Conditions that make the data hold function unavailable.

Single Data Recording

Recording the Current Measurement

Saving the current reading with REC and R symbols.

Restrictions on Single Data Recording

Conditions that make single data recording unavailable.

Accessing and Navigating Data Records

Activating/Deactivating Record Viewing

Activating or deactivating the data record viewing mode.

Viewing the Number of Stored Records

Accessing the count of stored data records.

Changing Data Record Display Modes

Switching display modes within data records.

Viewing Recorded Data Date and Time

Accessing the date and time of recorded data.

Switching Temperature Unit in Records

Changing temperature unit while viewing records.

Exiting Record Viewing Mode

Procedure to leave the data record viewing mode.

TM-188D Auto Data Logger

Activating Auto Data Logger Mode

Activating the auto data logger function.

Deactivating Auto Data Logger Mode

Deactivating the auto data logger function.

Restrictions on Auto Data Logger Mode

Conditions that make auto data logger mode unavailable.

Maximum/Minimum (MAX/MIN) Values

Entering MAX/MIN Value Mode

Activating the maximum/minimum display mode.

Cycling Through Max and Min Values

Cycling between maximum and minimum values.

Exiting MAX/MIN Value Mode

Procedure to leave the MAX/MIN mode.

Restrictions on MAX/MIN Mode

Conditions that make MAX/MIN mode unavailable.

TM-188D USB Connectivity

USB Connection Status Indicator

Indication on the LCD when USB cable is connected.

Setting and Calibration Procedures

Entering Setting and Calibration Mode

Instructions to access the meter's setting and calibration menu.

WBGT Alarm High/Low Setting

Setting high/low thresholds for WBGT alarms using figures A & B.

Initiating Settings and Changing Units

Initiating setting mode and changing temperature units.

Adjusting Digits and Changing Values

Selecting digits to adjust and changing parameter values.

Saving Settings

Confirming and saving the applied settings.

Setting the Year (Fig. C)

Procedure for setting the year on TM-188D.

Setting Month and Date (Fig. D)

Procedure for setting month and date on TM-188D.

Setting Hour and Minute (Fig. E)

Procedure for setting hour and minute on TM-188D.

Setting Seconds (Fig. F)

Procedure for setting seconds on TM-188D.

Setting Sampling Interval (Hours/Minutes)

Setting sampling interval in hours and minutes on TM-188D.

Setting Sampling Interval (Seconds)

Setting sampling interval in seconds on TM-188D.

Clearing Data Records (Fig. I)

Procedure for erasing stored measurement data.

Air Temperature Offset Calibration

Calibrating the air temperature sensor offset.

Humidity Offset Calibration

Calibrating the humidity sensor offset.

Black Globe Temperature Offset Calibration

Calibrating the black globe temperature sensor offset.

Thermal Hazard Prevention Standards

Heat Stress Exposure Criteria (WBGT)

Table of WBGT values for heat stress assessment.

Activity Examples by Metabolic Rate

Examples of physical activities categorized by metabolic rate.

Operational Precautions

Avoiding Electromagnetic Interference (EMI)

Warning about EMI affecting meter readings.

Caution: Do Not Touch Black Ball

Caution against touching the black ball during measurements.

Black Ball Deformation Impact on Accuracy

Warning about deformation affecting measurement accuracy.

TM-188D Software Installation Guide

Step-by-step guide for installing the TM-188D software.

Downloading Software and Guides

Instructions to access the website and download software and guides.

Software Usage Instructions

Guidance for software usage and operation.

External DC Power Requirements

AC to DC Adapter Specifications

Voltage, current, and connector details for the DC adapter.

General Safety and Maintenance

Environmental Safety Precautions

Safety advice on avoiding direct sunlight and dampness.

Operating Altitude Limit

Maximum operating altitude for the meter.

Battery Replacement Procedure

Low Battery Warning and Replacement

Indication and action for low battery status.

Battery Removal for Long-Term Storage

Recommendation to remove battery during extended periods of non-use.

Installing a New 9V Battery

Steps for safely replacing the battery.

End of Life Disposal Information

Battery Removal When Not in Use

Warning to remove battery if meter is not used.

Waste Disposal Symbol Explanation

Explanation of the waste disposal symbol.

Related product manuals