7.16 Air Cleaner Removal / Inspection
The air cleaner is one of the most important maintenance items on the machine.
Regular inspection and replacement is necessary to ensure proper performance
and to prolong engine life. Inspect the air cleaner elements daily. If damaged
or heavily soiled, clean or replace the elements.
1. With the engine off and cool and the key removed from the ignition, open
the hood, release the latches on either side of the air cleaner, then remove
the cover.
2. Remove the primary element (1). The primary element can be cleaned and
reused up to five times, but should be changed at least once a year.
3. Remove the secondary element (2). The secondary element is not
serviceable or washable. The secondary element should be replaced every
three cleanings of the primary element.