FAULT POSSIBLE CAUSE SOLUTION
Engine shuts down Overloaded engine Reduce load
automatically and
TROUBLE LIGHT on Broken fan belt Inspect fan belt and replace as
CONTROL PANEL needed
is illuminated
Defective thermostat or Inspect thermostat
thermocouple switch switch
Defective water pump Inspect water pump and replace
if needed
Blocked cooling air inlet Inspect and remove any
or exhaust obstructions
Defective or grounded Inspect switch and repair or
temperature switch replace
Defective injectors or Have the engine inspected by a
injector pump trained service technician
Low crankcase oil level Check oil level and refill as
required
Defective oil pump Have the engine inspected by
a trained service technician
Defective or grounded oil Inspect switch and repair or
pressure switch replace
TROUBLESHOOTING (Cont.)