EasyManua.ls Logo

Terex T25 - T25 I; T45 I Specifications and Dimensions

Terex T25
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terex T25I and T45I Super Quiet Generator 37
Operating Instructions and Parts Manual
June 2006
REV A
T25I / T45I SPECIFICATIONS AND
DIMENSIONS
MODEL T25I T45I
POWER CAPABILITY-PRIME
kVA (kilovolt-amps) 25 45
kW 20 36
3 Phase Amp Ratings
208V 69 125
240V 60 108
480V 30 54
POWER CAPABILITY-STANDBY
kVA (kilovolt-amps) 30 50
kW (kilowatts) 24 40
3 Phase Amp Ratings 208V 83 139
240V 72 120
480V 36 60
VOLTAGE
3 Phase 208, 220, 240, 416, 440, 480 Standard Standard
600 Volt Optional Optional
1 Phase 120, 127, 139, 240, 254, 277 Standard Standard
Max Motor Starting1 Hp 12 27
kW 9 20
SKVA 70 165
DIESEL ENGINE
Manufacturer Isuzu Isuzu
Model 4LE1PV02 4JG1TPV
Cylinder 4 4
Air Intake (aspiration) Natural Turbo
Cooling System Std Rad Std Rad
Fuel Capacity (gal) 64 64
Run Time (75% load) 53 29
Fuel Consumption, Prime Power (gal per hr) 100% load 1.5 2.8
75% load 1.1 2.2
50% load 0.8 1.7
25% load 0.4 1.2
dBA 64 64
Controller Type Analog/Digital Analog/Digital
Start/Stop Controller Cascade Cascade
12V Battery (CCA) 750 750

Other manuals for Terex T25