Detailed descripon of the basic and advanced features of the IR transmier depends on
a given type (please see user manual aached to your IR transmier).
Examples of features of an IR transmier – type DT-IR1
– control of temperature inside the room (in Local Mode the device controls the
temperature of the radiator)
– possibility to program two temperature sengs: Comfort and Economical and easy
switch from one to the other
– automac temperature adjustment program for Comfort and Economical seng
during a 24hour period (24-hour mer)
– automac dryer program
– automac An-freeze program with possibility to adjust the operaon threshold
– possibility to adjust the temperature sensor according to the specic condions of
a given interior (calibraon feature).
The transmier sends a controlling signal every 10 minutes in order to check the quality
of communicaon between the two devices. Interrupon or lack of 3 subsequent signals
(30 minutes) will result in automac changeover of the KTX 4 controller to the Local
Mode with the “0” seng. The controller will wait for communicaon to resume (display
panel will show “0” and icon will start ashing). Having received the controlling signal,
the device will automacally return to remote operaon.
Problem
Device is connected to
electricity, LED display
panel is empty
Connecon problem Check the power wire
connecon, plug and the
socket
Heang element does not
heat, LED display panel
shows E1 or E2 code
Device signals emergency,
temperature sensor has
been damaged
Disconnect the device
completely from electric-
ity, wait for the radiator
to cool down and turn it
back on
Controller is incorrectly
installed on the heang
element
Check if the head of the
heang element is com-
pletely hidden. Release
the screw at the back
of the controller casing,
gently push the controller
towards the radiator and
secure the casing back
Short, single ashes of the
dash on the display panel
(in remote mode)
Controller is working
properly – ashes indicate
receipt of controlling sig-
nal from the IR transmier
—
Device automacally
switched from remote to
local mode
Communicaon problem:
sensor is inaccessible or
the devices have been
incorrectly set against
each other
Remove any objects that
may be disrupng com-
municaon between the
two devices or mount the
IR transmier in
a dierent locaon
Heang element is heang
despite being turned o
with the buon
Electronics damage Disconnect the device
completely from electric-
ity, wait for the radiator
to cool down and turn it
back on