5.6 STOVE LEVELLING
The stove must be levelled, with the help of a spirit
level,byregulatingtheadjustablefeet(ifincluded)g.
5.10).
A B = Spirit Level
5.7 CONNECTION TO UTILITIES
5.7.1 Electrical connection
It is sucient to connectthe stove to the electrical
system using the supplied plug.
The electrical connection (plug) must be easily
accessible even after installing the stove.
If the power cord is damaged, it must be replaced
bythetechnicalassistanceserviceorbyaqualied
technician in order to prevent any risk.
5.7.1.1 Earthing
The system must be earthed and equipped with a
dierentialswitchinaccordancewithlegislationinforce
(g.5.11).
Make sure the power cord does not come into contact
with hot parts.
Theuegasexhaustpipemusthaveitsownearth
connection.
5.8 OPTIMISATION OF COMBUSTION
Best combustion depends on a variety of factors (type
of installation, operating and maintenance conditions,
type of pellets, etc...)
Upontherstignition,thestove’scombustioncanbe
optimised.
Generally speaking, if there is a lot of residue in the
burn pot at the end of combustion, it is recommended
toadjustthecombustionconguration(increasingthe
value) until the most suitable solution is found.
See sections 9.17- 9.18 - 9.19.
5.9 VENTILATION
The stove is equipped with ventilation.
The air pushed by the fans keeps the appliance at
a low enough temperature, thus avoiding excessive
stress on the materials of which it is composed.
Do not close the hot air outlet vents with any objects
or the stove will overheat!
The stove is not suitable for cooking food.
ATTENTION: Do not cover the air vents.